Description
This kit is used to control condensate from the unit. Condensate water drains from the chassis into the sleeve during regular heat pump operation and during times of high humidity when the unit is in cooling operation. The drain kit allows the condensate from the outdoor and indoor coils to be routed to a suitable area.
It can be installed for either outdoor or indoor use. For outdoor use, the condensate can be drained from either the wall sleeve's right- or left-hand side. Local codes will determine the proper condensate disposal. For indoor use, the drain components must be installed on the bottom of the wall sleeve and connected to a drain system inside the building.
Note: This drain kit serves only as a link between the unit and the field-supplied condensate drain system. Installing the equipment without connecting it to a drainage system will result in inadequate condensate removal, possible leakage, and corrosion.
Algaecide: Most algaecide products will cause damage to the unit base pan or coils and should not be used. Contact your sales representative for the recommended algaecide pan treatment for your unit.