Key Takeaways
-
PTAC units heat and cool without the need for ducts.
-
Each room has its thermostat for improved efficiency.
-
Choose from electric or heat pump heating styles.
-
Proper installation prevents noise and leaks.
-
Match BTU and voltage to the room size.
The Little Box That Runs the Room
If you’ve ever stayed in a U.S. hotel, the humming unit under the window was a Packaged Terminal Air Conditioner, or PTAC. It slides through an exterior wall, so half of the machine sits outdoors and half indoors. Because the compressor, fans, coils, and controls all live in one metal shell, a PTAC ships as a single ready-to-run appliance. That “all-in-one” design is why PTACs are popular in hotels, senior housing, and some compact apartments—they eliminate the cost of ducts and allow each guest to adjust the temperature to their liking. Recent models are slimmer and more insulated than their 1990s counterparts, which means less noise and fewer drafts. For a deeper primer on the concept, see our self-contained PTAC explainer.
Looking for a compact and efficient unit for guest comfort? Shop R-32 PTAC Units
Main Parts You’ll Find Inside a PTAC
Open the front grille, and you’ll spot a washable air filter, an indoor blower wheel, and the evaporator coil. This coil captures heat from room air when the PTAC is cooling. Behind the metal partition sits the sealed refrigeration loop, comprising a compressor, an expansion device, and an outdoor condenser coil, along with a second blower that discharges heat outdoors.
The control board monitors temperature using simple thermistors and controls the compressor or heater as needed. A drain pan and small pump (found in many units) capture condensate and direct it outside, keeping carpets dry. Walls, sleeves, and exterior louvers are sold separately, but they last for three or four generations of PTACs before needing replacement, saving long-term costs.
Airflow Journey: Intake, Coil, and Back to You
Here’s the path in slow motion:
-
Room air is pulled through the front grille and filter.
-
The indoor blower pushes that air across the cold evaporator coil, where heat jumps into the refrigerant.
-
Cooled, dehumidified air flows back into the room through the top discharge vent.
-
The warm refrigerant travels through a sealed tube to the outdoor coil.
-
A separate fan blows outdoor air over that coil, sending the heat outside.
All this happens in seconds. A tight, level wall sleeve stops vibration, and a proper seal of foam or silicone blocks outside noise. For step-by-step prep, follow the PTAC installation tips.
Cooling Cycle Made Simple
The PTAC’s cooling mode resembles a window AC, but with better components. The compressor squeezes cool vapor into a hot liquid, raising its temperature. That hot liquid heads to the outdoor coil, where a fan strips away the heat. The now-warm outdoor air rises and exits above the sleeve. The refrigerant—still under pressure—drops through a small orifice (or an electronic expansion valve in newer units). Pressure falls, liquid flashes into a mist, and temperature drops sharply.
This cold mist flows through the indoor coil, stealing heat from the room air. By the time the mist returns to the compressor, it has boiled back into a low-pressure vapor, ready to begin the loop again. The thermostat instructs the board to cycle the compressor, ensuring the room temperature remains within approximately 2 °F of the set point.
Heating Modes: Strip Heat vs. Heat Pump
Most entry-level PTACs heat with electric resistance coils. Think of them as giant toasters—simple, cheap, but hungry for watts. Many 2025 models feature a reversing valve, allowing the refrigeration loop to operate in reverse as a heat pump. In heat-pump mode, the outdoor coil collects free heat from outside air, and the indoor coil releases it into the room.
When outside air is too cold for efficient heat pumping (below about 35°F), the unit automatically switches to its backup electric strips. Dual-mode PTACs reduce heating bills by approximately 25–40% in mild climates, as the compressor transfers heat rather than generating it.
In warm climates, dual-mode PTACs can cut your heating bill by up to 40%. Explore Heat Pump PTACs
Smarter Controls and Features in 2025
Mechanical knobs are fading. Today’s PTACs often pair with wall thermostats, Wi-Fi apps, or hotel energy-management systems. Occupancy sensors dim the fan when no one is in the room, and inverter compressors ramp down rather than start and stop, cutting noise and spikes in power draw. Some brands even let facility managers group units and push firmware updates remotely.
Energy Efficiency and Environmental Footprint
Efficiency metrics for cooling include the EER (Energy Efficiency Ratio) and the CEER (Combined EER, which accounts for standby losses). Values above 11 CEER are common in 2025 heat-pump PTACs, thanks to variable-speed fans and R-32 refrigerant’s better heat capacity.
During the heating season, look for COP (Coefficient of Performance) numbers near 3.0 when the heat pump is active, indicating that you receive three units of heat for every unit of electricity used. Swapping resistance-only units for inverter heat-pump PTACs can trim a typical U.S. hotel’s winter electric bill by hundreds of dollars per room. Our PTAC heat-pump energy guide breaks down real-world savings.
Common Issues and Quick Maintenance Routines
PTACs hate dust. A clogged filter restricts airflow and causes the compressor to run hotter, while dirt on the outdoor coil hinders heat transfer. Monthly filter rinses and quarterly coil vacuuming help maintain high efficiency. Don’t forget the drain pan, algae can plug the outlet hole and flood your carpet. Many units slide out on rails, allowing a technician to swap blowers or boards in minutes without disturbing the wall sleeve. Skipping these chores increases energy consumption and reduces compressor lifespan.
A tight-fitting sleeve cuts vibration and seals noise. Shop Wall Sleeves & Accessories
Picking the Right PTAC for Your Space
Start with size: multiply the room’s square footage by about 30 BTU for hotels or 25 BTU for well-insulated homes, round to the nearest standard size (e.g., 9,000 BTU, 12,000 BTU). Next, consider the voltage—most residential sleeves are 230 V, while older buildings may operate at 265 V. Determine if a heat pump suits your winter climate; in warm states, it quickly pays for itself. Check noise ratings under 54 dB for bedrooms. Finally, be sure the chassis fits your existing sleeve depth and height, or budget for a new sleeve.
Replacing an older wall unit? Browse R-32 Through-the-Wall Models
Frequently Asked Questions
Is a PTAC the same as a window AC?
No. PTACs are mounted through a wall and can heat and cool. Window units are installed in a window and typically only cool.
How often should I clean the filter?
Every 30 days in dusty areas, every 60 days in light-use spaces.
Can I run a PTAC on a standard 120V outlet?
Usually not. Most require 208–240 V. 120 V models are rare and have lower power.
What refrigerant do new PTACs use?
Most 2025 models use R-32 or R-454B, which are more eco-friendly than R-410A.
Why does my PTAC drip water indoors?
Likely a blocked drain or clogged filter causing condensation to back up.