Troubleshooting Guide What to Do If Your GE Wall AC Isn’t Cooling or Heating

When Mark’s GE 14,000 BTU 208/230 Volt Through-the-Wall Air Conditioner with Electric Heat (model AKEQ14DCJ) suddenly stopped cooling on a hot July day, he feared the worst: a costly repair. But after a quick inspection, he realized the culprit was nothing more than a clogged filter.

👉 Before calling for service, many issues with your GE wall unit can be solved at home with simple checks.

This guide provides a step-by-step troubleshooting roadmap to diagnose common problems when your GE wall unit isn’t cooling or heating properly.


🧭 Step 1: Start with the Basics

The simplest problems are often the most common.

🔌 Power Check

  • Confirm the unit is plugged into the 208/230V outlet.

  • Check the breaker box for a tripped breaker.

  • If the outlet feels loose or shows scorch marks, stop and call an electrician.

👉 Mark once thought his AC had failed—but it turned out the breaker tripped during a thunderstorm.


🧽 Step 2: Filter Inspection

A clogged filter is the #1 cause of weak cooling or heating.

What to Do

  • Remove the front grille.

  • Slide out the filter.

  • Wash with mild soap and water if reusable, or replace if disposable.

  • Let dry completely before reinserting.

👉 Mark found that cleaning his filter improved airflow so much that his living room cooled down in half the time.


❄️ Step 3: Cooling Issues

If your AC runs but doesn’t cool:

🔹 Common Causes & Fixes

  • Dirty Coils: Dust reduces heat transfer → Clean coils with a vacuum brush or coil cleaner.

  • Blocked Airflow: Furniture, curtains, or blinds obstructing vents → Move obstructions.

  • Thermostat Settings: Thermostat set too close to room temp → Lower setting by at least 5°F.

  • Oversized Room: Unit too small for space → GE 14,000 BTU covers 500–700 sq. ft. max.

🔹 Short Cycling (turns on/off quickly)

  • Cause: Oversized unit or thermostat sensor placed near heat sources.

  • Fix: Move lamps/appliances away from thermostat sensors.


🔥 Step 4: Heating Issues

The GE AKEQ14DCJ includes electric resistance heat, but sometimes problems arise.

🔹 Blowing Air but No Heat

  • Check if the unit is set to HEAT mode.

  • Verify the thermostat setting is above current room temp.

  • Reset breaker if tripped.

  • If coils never warm → likely heating element failure → requires a pro.

🔹 Weak Heating

  • Drafts from poorly sealed trim kit or wall sleeve.

  • Dirty filter restricting airflow.

  • Space too large or too cold (below 30°F).

👉 Mark found his GE unit heated comfortably at 40°F outside but struggled below freezing.


💧 Step 5: Drainage Problems

Water pooling indoors usually means improper drainage.

🔹 Causes & Fixes

  • Clogged Drain Pan: Clean pan and remove blockages.

  • Sleeve Tilt Issue: Sleeve must slope ¼ inch outward for drainage.

  • Debris in Drain Line: Clear with pipe cleaner or wet/dry vacuum.

👉 Mark fixed a leak by adjusting his sleeve tilt—simple but effective.


🔊 Step 6: Strange Noises

Your GE wall unit should hum quietly, not rattle or buzz.

🔹 Noise Types & Solutions

  • Rattling: Loose mounting screws or trim kit → tighten.

  • Buzzing: Electrical issue → call electrician.

  • Whistling: Air leaks around trim → reseal with silicone caulk.


🛠️ Step 7: When to DIY vs. Call a Pro

✅ Safe DIY Fixes

  • Cleaning/replacing filter

  • Vacuuming coils

  • Checking sleeve tilt & drainage

  • Tightening trim/seals

  • Resetting breaker

🚫 Pro-Only Repairs

  • Electrical smells, sparking, or repeated breaker trips

  • Failed heating element

  • Refrigerant leaks (oily residue or hissing sounds)

  • Compressor issues

👉 Mark’s rule: “If it’s electrical or refrigerant-related, I don’t touch it—I call a pro.”


📌 Mark’s Real-World Example

  • Problem: Weak cooling during July heat wave.

  • Initial Panic: Suspected compressor failure.

  • Troubleshooting: Removed filter—completely clogged with dust.

  • Fix: 5-minute cleaning.

  • Result: Full cooling power restored immediately.

👉 His experience proves that simple maintenance often solves the issue.


🧾 Troubleshooting Checklist

  • Is the unit plugged in and breaker not tripped?

  • Is the filter clean and airflow clear?

  • Are the thermostat settings correct?

  • Are coils clean and free of dust?

  • Is the wall sleeve tilted outward for drainage?

  • Is the trim kit sealed tightly?

  • Do noises point to loose parts or leaks?


💡 Preventing Future Issues

  • Clean filter monthly.

  • Inspect coils every spring and fall.

  • Check drainage at least once per season.

  • Reseal trim kit annually.

  • Run unit briefly in off-season to keep parts moving.

👉 Mark sets smartphone reminders each season for his maintenance checklist.


🔗 Verified References

  1. GE Appliances – Troubleshooting Guides

  2. Energy.gov – Common AC Problems and Solutions

  3. Family Handyman – How to Fix an Air Conditioner

  4. Consumer Reports – When to Repair vs. Replace Your AC

  5. Energy Star – Proper AC Maintenance


✅ Final Thoughts

If your GE 14,000 BTU through-the-wall AC isn’t cooling or heating:

  1. Start with simple checks: power, filter, thermostat.

  2. Move to airflow, coils, and drainage.

  3. Call a pro if issues involve electricity, refrigerant, or heating elements.

👉 Mark’s advice: “Don’t panic. Most problems are quick fixes. If it’s something major, the pros will let you know—but you’ll save time and money by ruling out the simple stuff first.”

In the next topic we will know more about: Do GE Wall Units Qualify for Energy Rebates or Tax Credits in 2025?

Mark callahan