The Propane Pressure Puzzle — Why Your Heater Isn’t the Problem, Your System Design Is

🛠️ Introduction: When a “Bad Heater” Isn’t Bad at All

Homeowners love blaming equipment. “This thing won’t stay lit.” “It won’t heat the shop.” “The burner’s weak.”

But I’ll tell you the hard truth after 25 years in the field:

Nine times out of ten, the heater is fine — your propane delivery system is the mess.

Propane heaters like the Reznor UDX 60,000 BTU Propane Unit Heater are workhorses. They’re built to last, built to tolerate cold garages, built to run in shops full of sawdust and metalwork.

But they can’t overcome poor pressure, wrong regulators, badly routed lines, or undersized pipes.

Propane pressure is not some optional detail.

It is the foundation of system design — and if you get it wrong, your heater will short-cycle, fail to ignite, run cold, burn dirty, or shut down for “no reason.”

This article breaks down the entire propane pressure puzzle in Tony-style plain English — no fluff, no mystery math.


🔧 1. Why Propane Pressure Is the First Design Step — Not the Last

You can size BTUs perfectly. You can mount the Reznor UDX at the right height. You can vent it beautifully.

But if the heater doesn’t get the correct propane pressure? Game over.

The two pressures that matter:

  • Tank pressure (varies with temperature)

  • Manifold pressure (what the heater actually needs to burn cleanly)

Most propane unit heaters want:

  • 11 inches water column (WC) at the inlet

  • 10 inches WC manifold pressure during operation

If your system design drops the inlet below ~11" WC, your heater begins acting “broken”:

  • Weak flame

  • Delayed ignition

  • Burner rollback

  • Cycling on high-limit

  • Soot buildup

  • Noisy combustion

  • Blower running cold

And yes — this all traces back to supply pressure, NOT the heater.


📉 2. The Hidden Flow Restrictors You Didn’t Know You Installed

Every homeowner thinks the propane company “already sized everything.”
Nope. The tech shows up, drops a tank, checks the regulator, and leaves.
But the actual run from the tank to your heater is your responsibility.

Here’s what’s quietly killing your pressure:

❌ Undersized flex line

That cute 3/8" flex connector from the hardware store?
It’s choking a 60K BTU heater to death.

❌ Too many elbows

Every 90° elbow = 5–10 feet of effective pipe length lost.

❌ Excessively long runs

Propane hates long, narrow pipes. It’s like trying to drink a milkshake through a coffee straw.

❌ Wrong type of pipe

Soft copper with too many bends loses pressure fast.
Black iron is better, but must be sized correctly.

Tony’s rule of thumb:

If your heater is starving, the line is almost always too small — not too long.

But both matter.


🧪 3. The Pressure Drop Reality Check (Tony’s Simple Test)

Before you touch the heater or call Reznor support, run this simple test.

🔍 Step 1: Measure static pressure at the heater gas valve

Use a manometer.

You should see: 11" WC (or slightly higher)

🔍 Step 2: Fire the heater and measure dynamic pressure

When the gas valve opens and the burner lights, you should see:
10–10.5" WC

If static pressure is fine but dynamic pressure drops:

Your gas line is too small or too long.
Heater is NOT the problem.

If both static and dynamic are low:

Your tank regulator or second-stage regulator is the problem.

If dynamic pressure rises during firing:

Your venting is blocked or combustion air is restricted.

This test tells you 80% of everything you need to know in 5 minutes.


🎯 4. How Wrong Regulators Destroy Performance (Quietly)

Propane regulators are not “all the same.”
The biggest mistake I see is homeowners buying the wrong regulator — usually a grill regulator or a high-pressure camping regulator.

Most home/shop propane systems need:

  • First-stage regulator at the tank (10–15 psi)

  • Second-stage regulator at the building (11” WC)

When this setup is wrong, the heater loses performance instantly.

Common homeowner mistakes:

  • Using a single second-stage regulator on a long run

  • Using a high-pressure-only regulator

  • Using grill regulators (not enough flow)

  • Installing regulators backwards

  • Putting the second-stage regulator too far from the appliance

A Reznor UDX can’t compensate for a bad regulator.


🧰 5. Why Pipe Sizing Charts Save More Heaters Than Technicians Do

Before running pipe, use verified ASME propane pipe sizing charts:
https://codes.iccsafe.org/content/IMC2021P1/chapter-4-ventilation

Then cross-check with a second fuel-delivery source

Rinnai Propane Gas Pipe Sizing Guide

You’ll learn real fast that:

  • 3/8" pipe can’t feed a 60K heater longer than ~10–15 feet

  • 1/2" pipe can’t always handle long runs

  • 3/4" pipe is usually required for 40+ foot runs

  • 1" pipe is needed for long or multi-branch systems

Tony says it plainly:

If your propane line isn’t at least 3/4" for long runs, don’t expect full BTUs.


🔥 6. Tank Placement — The Silent Pressure Killer

Nobody thinks their tank placement is a system-design problem.
It is.

Propane pressure changes with temperature

At 0°F, tank pressure is roughly 24 psi.
At 60°F, it’s closer to 92–100 psi.
Chart: https://inspectapedia.com/plumbing/LP_Gas_Pressures.php

If your tank sits:

  • in a snowbank

  • behind the north wall

  • unsheltered

  • half-empty during winter

Your pressure WILL drop.
Your heater WILL act up.

Best practice

Place the tank where it gets some sun but isn’t vulnerable to direct overheating.


↕️ 7. Elevation and Pressure: The Factor 99% of Homeowners Ignore

The higher you go, the lower the atmospheric pressure — and the worse propane appliances behave.

Above 2,000 ft, you must consider:

  • Lower BTU output

  • Lower combustion efficiency

  • Pressure adjustments

  • Different orifice sizes (in some models)

Verified reference:
https://www.nfpa.org/NEC/NEC-adoption-and-use/Additional-resources/Propane-Systems

If you live in mountain country and your heater “seems weak,” your design may need an altitude adjustment.


🌀 8. Cold Weather = Cold Propane = Low Pressure

Propane boils at -44°F.
But its usable pressure drops as outdoor temperature drops.

This is the #1 reason heaters fail in cold shops.

If you run two or more appliances, or a large unit heater, you MUST:

  • Use a larger tank

  • Keep it at least 30–50% full

  • Shelter it from extreme cold

  • Use proper regulators designed for low temps

Reference: https://www.propane.com/

In freezing weather, a 20-lb or 40-lb tank is not enough for a 60K BTU unit heater.
It will frost over, and your heater will sputter.


🏗️ 9. The Multi-Appliance Trap — Splitting Lines Drops Pressure Fast

Do you also run:

  • A garage heater

  • A gas stove

  • A water heater

  • A tankless heater

  • Or a backup generator on propane?

Your line is undersized unless the entire system was designed as a multi-appliance tree, not a daisy chain.

Every branch steals pressure.
Every tee creates turbulence.
Every device firing raises the demand.

How Tony designs multi-line propane:

  1. Run a large trunk line (¾" or 1")

  2. Branch off with shorter drops

  3. Use individual shutoffs

  4. Calculate total BTU load, not per-appliance load

This is how you keep every device happy.


🧱 10. The Shop Reality: Dust, Dirt & Airflow Affect Combustion Too

Propane burners are sensitive.
They need fresh air and correct pressure to burn clean.

If your environment contains:

  • Sawdust

  • Paint fumes

  • Metal grinding dust

  • Automotive chemicals

  • Welding smoke

Then your heater may struggle even with proper gas pressure.

Tony’s rule:

Poor combustion air can make a perfectly sized propane line look undersized.

Simplest fix:
Install the Reznor UDX as a sealed-combustion/direct-vent setup so it pulls air from outdoors, not your dusty shop.


📏 11. Real-World Examples: What Homeowners Get Wrong (Tony’s Case Notes)

Case 1: “The heater only runs for 3 minutes.”

Cause: 3/8” flex connector, 20 feet too long.
Fix: ¾" black iron run.
Outcome: Perfect heat.

Case 2: “Burner is fluttering.”

Cause: Frosted tank (20 lb) feeding a 60K BTU heater in 10°F weather.
Fix: 100 lb tank + regulator swap.
Outcome: Solid flame, no flutter.

Case 3: “Soot on the ceiling.”

Cause: Poor combustion air + wrong regulator.
Fix: Direct vent kit + correct second-stage regulator.
Outcome: Clean burn.

Case 4: “Flame pops on startup.”

Cause: Pressure too low during dynamic flow.
Fix: Upsized pipe and relocated second-stage regulator.
Outcome: Smooth ignition.


🧯 12. Pressure-Proof Setup: Tony’s Checklist for a Rock-Solid Propane Heater

If you want your unit heater to run flawlessly for 20+ years, follow this list:

✔️ 1. Use a proper two-stage regulator system

✔️ 2. Keep tank at least 30% full in winter

✔️ 3. Use ¾" or 1" pipe for long runs

✔️ 4. Minimize elbows

✔️ 5. Use a manometer to verify

✔️ 6. Keep regulator protected from ice and snow

✔️ 7. Vent the heater correctly

✔️ 8. Provide fresh combustion air

This is real system design — not guesswork.


🚀 Conclusion: Stop Blaming the Heater — Fix the System Design

Your propane heater — especially something as reliable as the Reznor UDX 60,000 BTU Propane Unit Heater — is almost never the villain.

Propane pressure is.

If the heater isn’t getting 11" WC at the inlet and 10" WC during firing, it’s not going to deliver its rated BTUs, no matter how new or expensive it is.

Once you fix:

  • pipe sizing,

  • regulator type,

  • tank placement,

  • line length,

  • elevation,

  • and cold-weather pressure behavior…

Your heater will run like the workhorse it was designed to be.

And that’s why I say it every single day:
Your heater isn’t the problem — your system design is.