Step-by-Step Installation Planning for PTAC Heat Pumps

Step-by-Step Installation Planning for PTAC Heat Pumps

Installing a PTAC heat pump isn’t rocket science, but it is a project that rewards careful planning. Whether you’re upgrading a single hotel room, outfitting an entire senior living facility, or adding comfort to a sunroom at home, the success of your PTAC installation depends on the prep work you do before the unit arrives.

In this guide, I’ll walk you through the step-by-step planning process—covering everything from sizing and wall prep to electrical requirements and long-term PTAC heat pump maintenance. With the right plan in place, you’ll save money, avoid costly mistakes, and ensure your PTAC heat pump delivers comfort year-round.


Why Installation Planning Matters

Many people assume installing a PTAC is as simple as “cut a hole in the wall and plug it in.” That’s partly true—the design of PTACs makes them easier to install than central HVAC systems or ductless mini-splits. But poor planning can lead to:

  • Air leaks and reduced efficiency

  • Electrical overloads or code violations

  • Drainage issues and water damage

  • Units that are noisy, poorly sized, or underperforming


Step 1: Determine the Right Size

The first step in any PTAC installation is choosing the correct BTU rating for the room.

General Rule of Thumb

  • 20 BTUs per square foot of living space.

Example:

  • A 350 sq. ft. hotel room → 7,000 BTUs minimum.

  • With sun exposure, multiple occupants, and appliances, a 9,000–12,000 BTU unit is more realistic.

👉 For help calculating size, see the DOE’s Air Conditioner Sizing Guide.

Oversizing is one of the most common mistakes. A unit that’s too powerful will cycle on and off frequently, leading to uneven temperatures and shorter equipment life.


Step 2: Choose the Right Wall Sleeve

A wall sleeve is the metal housing that holds your PTAC unit in place. It’s typically 42" wide, but depth and design vary.

  • New Installations: Buy a sleeve that matches your PTAC brand and model.

  • Replacement Units: Check if your old sleeve is compatible with the new unit. If not, replace it.

Tip: Don’t reuse a damaged sleeve—it can compromise the seal and cause water leaks.


Step 3: Prepare the Wall Opening

Your PTAC heat pump needs a precise opening in the wall:

  • Width: Standard PTACs are 42" wide.

  • Height: Usually 16" tall.

  • Depth: Around 13–16", depending on the unit.

Make sure the wall opening:

  • Has structural reinforcement to support the unit’s weight.

  • It is properly framed to prevent shifting.

  • Includes a slight outward slope (about ¼ inch) for proper drainage.

👉 For exact dimensions, always check the manufacturer’s installation manual. For example, Amana PTAC Installation Instructions provide detailed wall prep diagrams.


Step 4: Electrical Requirements

PTAC units come in different voltages and amperages. Choosing the wrong one can lead to tripped breakers—or worse, unsafe conditions.

Common PTAC Configurations:

  • 230/208V (most common in hotels and commercial applications)

  • 265V (often used in older or specialized buildings)

  • 115V (for smaller residential or light commercial spaces)

Check the following before installation:

  • Your building’s electrical service

  • Circuit breaker capacity

  • Outlet type and location

👉 The National Electrical Code (NEC) sets standards for safety—always make sure your wiring complies.

Pro Tip: Hire a licensed electrician to verify compatibility and install the dedicated circuit.


Step 5: Drainage Planning

All PTAC heat pumps produce condensate during cooling. Without proper drainage, you risk leaks, mold, or water damage.

Options include:

  • Internal Sloped Sleeve Drainage: Water flows outdoors naturally if the sleeve is installed correctly.

  • Drain Kits: Attach to the unit for directed drainage indoors or outdoors.

  • Secondary Pan: In sensitive areas, install a backup pan to catch overflow.


Step 6: Ventilation & Fresh Air

Most PTAC units include a small vent door that allows outdoor air intake. Decide in advance whether you want to use this feature.

  • Pros: Brings in fresh air, improves indoor air quality.

  • Cons: Can reduce efficiency and introduce humidity in hot climates.

Some modern PTAC heat pumps meet the ENERGY STAR Draft PTHP specification, which requires reporting on fresh-air capability.


Step 7: Consider Heating Backup

Remember: PTAC heat pumps provide efficient heating in moderate climates, but efficiency drops in freezing temperatures.

  • Below 25–30°F, most units switch to electric resistance backup heat.

  • Plan electrical load accordingly.

  • If your building is in a cold climate, factor in higher winter operating costs.


Step 8: Noise Control

Noise is a common complaint in poorly planned PTAC installs. To minimize it:

  • Install the sleeve correctly with weather stripping.

  • Use vibration isolators if needed.

  • Choose models with quiet fan designs.

Tip: Hotels often specify max decibel levels for guest satisfaction—something to keep in mind if you’re managing multi-unit properties.


Step 9: Plan for Controls & Thermostats

Modern PTACs can connect to:

  • Built-in controls (basic knob or digital panel).

  • Wall thermostats (wired or wireless).

  • Smart/connected systems (for energy management in hotels or apartments).


Step 10: Maintenance Access

Don’t just think about installation—plan for ongoing maintenance:

  • Leave clearance for filter changes and coil cleaning.

  • Ensure the drain pan is accessible.

  • Keep outdoor vents free of obstructions.

Pro Tip: Create a schedule. For hotels, monthly filter checks are a must.


Step 11: Professional vs. DIY Installation

Yes, PTAC units are designed for straightforward installation. But here’s the reality:

  • DIY Friendly: Single room additions, replacements in existing sleeves.

  • Professional Recommended: Large projects, electrical modifications, new wall openings, multi-unit facilities.

Hiring a pro ensures compliance with codes and avoids costly mistakes.


Step 12: Commissioning & Testing

Once installed:

  • Test both heating and cooling functions.

  • Check for air leaks around the sleeve.

  • Confirm proper drainage.

  • Listen for unusual noise or vibration.

A professional commissioning process ensures your system is performing as designed.


Example Installation Plan

Let’s walk through a real-world scenario.

Scenario: Hotel Renovation in Dallas, TX

  • 120 guest rooms, each ~325 sq. ft.

  • Existing sleeves are in place but need replacement.

  • Climate: hot summers, mild winters.

Plan:

  • Size units at 9,000–12,000 BTUs.

  • Replace all sleeves with new insulated models.

  • Install drain kits with outdoor discharge.

  • Use 230V, 20-amp circuits per unit.

  • Connect units to a central EMS for energy monitoring.

Result: Guests enjoy comfort, management saves on utility bills, and installation is smooth.


Final Thoughts

Planning a PTAC heat pump installation is all about details—sizing correctly, prepping the wall opening, confirming electrical requirements, and setting up drainage and ventilation.

While PTACs are easier to install than many other HVAC systems, careful preparation is essential to ensure efficiency, comfort, and long-lasting performance.