🧮 Square Footage vs. System Size — The Real Math Mike Used for His 2-Zone Setup


🏠 1) Why System Size Matters More Than You Think

When I first started shopping ductless, I thought system sizing was simple: square footage × a BTU number on a chart. Then I watched two neighbors with identical floor plans end up with totally different comfort—and utility bills—because of sun exposure, insulation, and ceiling volume. That’s when I stopped trusting generic charts and started running real numbers.

  • Undersized = runs nonstop on hot days, misses the thermostat, and feels mushy in humidity.

  • Oversized = short cycles, doesn’t remove moisture, costs more upfront and to run, and wears out faster.

Before I bolted the brackets for my MRCOOL DIY 5th-Gen 27,000 BTU 2-Zone (9k + 18k), I sized each zone using Manual J principles (the same logic pros use), then validated with live sensors after install.


📏 2) “20 BTU per sq ft” Is a Starting Point—Not a Rule

You’ll see the rule of thumb everywhere: ~20 BTU/ft². It assumes:

  • 8-ft ceilings

  • Average window area with average orientation

  • Decent insulation and air sealing

  • Moderate humidity

  • No wild internal heat gains

Most houses deviate from that ideal in at least three ways. Mine sure did.

Pro Reality Check: Energy.gov and ENERGY STAR both say proper sizing depends on envelope, infiltration, solar gain, and occupancy, not just square footage. Take “20 BTU/ft²” as a draft—then correct it.


🧾 3) My House Data (So You Can See the Adjustments)

Space Area (ft²) Ceiling Height Orientation / Sun Notes Zone / Head
Living + Kitchen 450 Vaulted ~10 ft South, big glass Open plan; cooking adds internal load 18,000 BTU
Bedroom + Office 250 8 ft East, modest glass Quieter load, morning sun 9,000 BTU

Total cooled floor area: ~700 ft². But remember: volume and solar change the game.


📐 4) The Load Math I Actually Ran (Manual J-lite)

I didn’t buy full Manual J software for this one, but I used the same logic:

Base equation (simplified):
[
\textbf{BTU} \approx \text{Area (ft²)} \times \text{Load Factor (BTU/ft²)}
]

Then I adjust the result for:

  • Ceiling Height (volume correction)

  • Climate Zone (humidity & design temps)

  • Windows & Orientation (solar gain)

  • Envelope Quality (insulation & leakage)

  • People & Appliances (internal gains)

My starting load factors

  • Living/Kitchen: ~35 BTU/ft² (vaulted, south glass, cooking gains)

  • Bedroom/Office: ~25 BTU/ft² (shaded, lower activity)

Raw loads:

  • Living/Kitchen: 450 × 35 = 15,750 BTU

  • Bedroom/Office: 250 × 25 = 6,250 BTU

  • Subtotal: ~22,000 BTU

That’s not the final answer—keep going.


☀️ 5) Climate Zone & Humidity Adjustment

I’m in a humid, warm climate (think NOAA’s humid subtropical areas). Humidity load is real; you can feel it.

My rule of thumb (from experience + climate tables):

  • Cooling factor: +10% to +15% for hot-humid

  • Heating factor: often lower in the South, but check design temps

I used +15% for cooling. See climate references on NOAA and design guidance in ACCA/ASHRAE docs (ASHRAE Standards).


📦 6) Ceiling Height / Volume Correction

Per-square-foot rules assume 8-ft ceilings. My living area peaks around 10 ft. That’s 25% more air to condition.

Ceiling factor:
[
\text{CF} = \frac{\text{Actual height}}{8} = \frac{10}{8} = 1.25
]

I apply that factor to the living area portion of the load because that’s where the vault is.


🪟 7) Glass, Insulation & Occupancy

  • South-facing glass adds significant solar gain. A rough, conservative adder is 1,000–1,500 BTU per 100 ft² of sun-exposed glass on peak days.

  • Envelope matters: attic at R-30 (decent), walls around R-13 (average), and I’ve chased down some infiltration, but an older door still leaks.

  • People add load. I count ~400 BTU/person as a simple, real-world number when a space is regularly occupied.


🧪 8) Walkthrough: The Numbers I Landed On (Examples)

8.1 Bedroom/Office (9k head)

  • Base: 250 × 25 = 6,250 BTU

  • Climate factor (+15%): 6,250 × 1.15 = 7,188 BTU

  • Ceiling factor: 8-ft → no change

  • Window gain: modest → negligible adder

  • Occupancy: 1–2 people in mornings → +300–500 BTU (peak)

Peak target: ~7,500 BTU9,000 BTU head gives me headroom and quiet modulation.

8.2 Living + Kitchen (18k head)

  • Base: 450 × 35 = 15,750 BTU

  • Ceiling factor 10 ft: 15,750 × 1.25 = 19,688 BTU

  • Climate factor (+15%): 19,688 × 1.15 = 22,641 BTU

  • Sun & glass adder (conservative): +1,000–2,000 BTU

  • Cooking/internal gains (peak use): +500–1,000 BTU

Peak target: ~24,000–25,000 BTU.
A full 24k head would be feasible but less flexible when doors close or occupancy shifts. The 18k head has been perfect because:

  • I keep air paths open (return path under doors, a small transfer grille),

  • I rely on longer modulating cycles for humidity removal,

  • The 9k handles the adjacent rooms, so the system capacity fits the whole space.


🧊 9) Why I Landed on the MRCOOL 27k 2-Zone (9k + 18k)

Two reasons:

  1. Load mapping, not house total: My home behaves like ~22–25k BTU at peak cool across both spaces. The paired heads distribute capacity where it’s needed.

  2. Modulation wins: Ductless heads are efficient when they modulate—they like longer, steadier runs. Going massively oversized ruins that.

Cross-check performance in the AHRI Directory for real, certified ratings on specific outdoor/indoor head matchups.


⚠️ 10) Oversizing: The Four Pains You Feel Immediately

ENERGY STAR calls this out plainly—and they’re right: Right-Sizing AC

  1. Short-cycling: Unit hits setpoint fast, shuts off, never dehumidifies.

  2. Clammy rooms: Temp says 72 °F, but RH stays in the 55–65% swamp zone.

  3. Higher bills: Compressors are least efficient when ramping on/off constantly.

  4. Wear & noise: More starts = more wear; blasts of cold air = comfort swings.

In humid climates, moisture removal matters more than raw BTU. Correctly sized equipment stays on longer at low speed and wrings water out of the air.


📊 11) Post-Install Validation (Real-World Data)

I don’t guess; I measure. Here’s what my sensors showed over the first summer:

Metric 18k Zone (Living) 9k Zone (Bedroom)
Avg summer runtime/day 4–6 hours 2.5–4 hours
Average RH (peak months) 45–50% 43–48%
Temperature swing at setpoint ±1.5 °F ±1.0 °F
Energy use (kWh/day) 7–10 4–6

Translation: cycles are long and steady, humidity sits in the comfort pocket, and the heads don’t blast or hunt. That’s the fingerprint of good sizing.


🧰 12) Low-Cost Tools That Make You Dangerous (in a Good Way)

  • Laser distance meter — accurate area in seconds

  • IR thermometer — supply air temps and delta-T checks

  • Watt-meter (smart plug) — track kWh by head or whole system

  • Humidity/Temp sensors — I like one per zone + one in a hallway

  • Anemometer (optional) — spot airflow, especially if you add deflectors


🌿 13) R-32 Refrigerant: Why It Helps the Numbers

The 5th-Gen MRCOOL uses R-32, which (compared with legacy R-410A):

  • Improves heat transfer, enabling higher efficiency in practice

  • Requires lower charge mass for the same capacity

  • Supports compact coil designs with better seasonal performance

Read the refrigerant transition background at the EPA. Don’t get wrapped around the axle on the chemistry—just know that modern systems can deliver the same comfort with less input power when they’re sized and installed right.


🧠 14) My Practical Sizing Rule (After Doing This a Bunch)

If you want a one-liner that bakes in the big factors:

[
\boxed{\textbf{BTU} \approx \big(\text{Area} \times \text{Load Factor}\big) \times \text{Ceiling Factor} \times \text{Climate Factor} \times \text{Usage Factor}}
]

Where:

  • Load Factor = 25–35 BTU/ft² (25 for shaded bedrooms; 30–35 for sun-soaked open living spaces)

  • Ceiling Factor = Height ÷ 8 (e.g., 10 ft → 1.25)

  • Climate Factor = 0.9–1.2 (cool-dry to hot-humid)

  • Usage Factor = 1.0–1.1 (add ~0.05–0.10 for heavy cooking/people/equipment)

Worked examples (mine):

  • Bedroom: 250 × 25 × 1.00 × 1.15 × 1.00 ≈ 7,187 BTU → 9k head chosen

  • Living: 450 × 35 × 1.25 × 1.15 × 1.05 ≈ 23,773 BTU (peak) → 18k head + system diversity

If your result straddles sizes, decide based on humidity control and modulation rather than badge BTUs alone.


🧭 15) When to Pull in a Pro (and Why I Still Did)

DIY doesn’t mean do it blind. I paid a local pro ~$150 for a one-hour sanity check with Manual J software against my numbers. Totally worth it for peace of mind and paperwork if you’re chasing rebates/tax credits. Start with ACCA’s directory or ask your utility.


📦 16) 2-Zone vs. 1 Bigger Head (Or 3-Zone): Capacity Placement Matters

Why I prefer 9k + 18k instead of a single 24k head:

  • Door control & privacy: Bedrooms get their own climate without over-cooling the main space.

  • Load coupling: Kitchens spike during cooking; bedrooms don’t. Split capacity lets each zone modulate independently.

  • Noise & comfort: Smaller heads at lower fan speeds are whisper-quiet and keep RH tight.

Why not a 36k 2-zone? Because I’d be paying for capacity I can’t use efficiently. It would short-cycle in shoulder seasons and miss RH targets. Ask me how I know (my first system years ago…).


🧯 17) Common Sizing Mistakes I See (and How to Avoid Them)

  1. Sizing to total house area instead of per zone.

  2. Ignoring ceiling height (volume).

  3. Using a “sunny state” load factor for a shaded north-facing bedroom.

  4. Bigger is better—it isn’t, especially for humidity.

  5. No plan for return air paths when doors are closed (use transfer grilles or undercut doors).

  6. Not checking line-set lengths and elevation against manufacturer tables.

  7. Skipping a leak-check and deep vacuum, which kills performance no matter how perfect your math is.


🧼 18) After Sizing Comes Tuning (Fast Checklist)

  • Airflow: Start at medium fan, auto mode for a week.

  • Setpoints: In humidity, set 1–2 °F lower for a week to let RH come down.

  • Schedules: Run the bedroom head pre-cool for 60–90 minutes before use.

  • Deflectors: If you feel stratification in the vaulted space, a tiny deflector or fan setting change usually fixes it.

  • Filters & coils: Clean quarterly in pollen/dust areas. DOE guidance is helpful: Energy.gov AC Tips


🧮 19) Mini “Pocket Calculator” You Can Steal

Step A — Choose Load Factor:

  • 25 BTU/ft² = shaded, insulated bedroom/office

  • 30 BTU/ft² = average living room

  • 35 BTU/ft² = sun-exposed, open plan or big glass

Step B — Apply Multipliers:

  • Ceiling: height ÷ 8 (e.g., 10 ft → 1.25)

  • Climate: 0.9 (cool-dry) to 1.2 (hot-humid)

  • Usage: 1.0 (typical) to 1.1 (busy kitchen/people/equipment)

Step C — Sanity Adders (peak days):

  • +300–500 BTU for each extra regular occupant in that zone

  • +1,000–2,000 BTU if you have a lot of south/west glass in the zone

Step D — Pick the Head:

  • If you’re within 10–15% of a head size, err toward the smaller if humidity is a concern and you have solid modulation and long cycles.


🧪 20) Case Studies (So You Can See the Edges)

Case A — The “Looks Identical” Living Room That Isn’t

Two neighbors, same 450 ft² living rooms. One faces north (trees), one faces south (glass). North house runs 30 BTU/ft², south house needs 35+. That’s a ~20% swing before volume and climate factors.

Case B — The 9k Bedroom That Should Have Been 12k

A friend insisted on 9k for a 300 ft² loft bedroom with a low knee wall and roofline windows—11 ft average height and zero shade. Quick math:

  • 300 × 30 × (11/8) × 1.1 ≈ 13,612 BTU → a 12k would have covered the real peak; the 9k runs hot all August.

Case C — The “Buy a 36k Just in Case” Plan

A homeowner replaced a 24k with a 36k for a 700 ft² main floor. Cooling felt colder—but wetter. RH stayed at 58–62%. We swapped to a 27k 2-zone mapped to usage, and RH fell to 45–50% with fewer hot/cold swings and lower bills. Bigger felt better for a week; measured better won forever.


🌀 21) Dehumidification: The Hidden Half of Comfort

If you only look at dry-bulb temperature, you’ll chase your tail. Comfort is temp + humidity. Properly sized, modulating systems spend most of their life at low compressor speed, riding along the sensible/latent line and wringing moisture out.

  • Target RH: 40–50% in summer.

  • If you sit above 55%, first suspect oversizing or short cycling, not lack of raw BTU.

  • Night setbacks that cause rapid cool-downs can spike RH; try smaller setbacks.


🧩 22) Zoning Strategy: Doors, Paths, and “Invisible Ducts”

Ductless is “ductless,” but air still needs paths:

  • Undercut interior doors by 3/4–1 inch or add a transfer grille (bedroom → hall).

  • In open plans, place the head where it “sees” the biggest heat sources (sun + kitchen).

  • Avoid blowing directly at thermostats or across short walls that cause bounce-back cycling.

  • If you have a stairwell, treat it like a chimney; mind stratification with fan settings or a small return path.

These airflow details don’t change calculated load, but they decide whether your chosen capacity feels right.


🔋 23) SEER2/HSPF2 and Why I Don’t Chase the Highest Number Blindly

Higher SEER2/HSPF2 helps, but match matters first:

  • A perfectly matched SEER2 20 that runs long/steady can beat a SEER2 24 that short-cycles.

  • Ratings are lab conditions; your climate, zoning, and envelope decide if you’ll ever see those numbers.

  • Use the AHRI Directory to check the exact outdoor + indoor head pairing you plan to buy. Pick a high-efficiency pair that fits your load map, not just the biggest number in the brochure.


🧮 24) Quick Audit: Are You Over or Under?

  • RH stays >55% even when it’s cool? → Likely oversized (or airflow/balance issue).

  • Unit runs full tilt for hours and still misses setpoint? → Likely undersized (or envelope leak).

  • Temp swings ±3–4 °F with short blasts? → Oversized or airflow/thermostat placement problem.

  • Long, quiet cycles with RH 40–50% → You nailed it.


🧭 25) When to Upsize (Legit Reasons)

  • You host 6–8 people nightly in one zone (home daycare, big family dinners).

  • You add big west-facing glass with no shading.

  • You’re planning future conditioning of adjacent space via open doors (e.g., finishing a connected room).

  • You live at high altitude with big solar gain (dry but high insolation can still push sensible load).

Even then, I’d rather add shading (awnings/film) and air sealing first. It’s cheaper to shrink the load than to drag a bigger compressor around for 15 years.


🧭 26) Rebates & Paperwork (Sizing Helps)

Correct sizing isn’t just comfort—it helps pass QA for rebates and tax credits. Many programs require equipment matched to calculated load and AHRI-verified pairings:

  • Start here: ENERGY STAR Rebate Finder

  • Check federal/utility incentives at Energy.gov and with your local utility

  • Keep your Manual J summary (or pro sign-off), model numbers, and AHRI certificate in a simple PDF


🧩 27) Frequently Asked Questions (Real Ones I Get)

Q: My house is ~1,400 ft². Is 27k enough?
A: Maybe—or not. Total house area is the wrong lens. If you’re conditioning 700–900 ft² of the day-to-day living areas with good envelope, 27k 2-zone often fits. If you’re trying to do the whole 1,400 ft² with doors closed, probably not. Do the zone math.

Q: I’m dry-climate (high desert). Same math?
A: Mostly, but your climate factor may be 0.95–1.00 and your solar gains might be higher. Watch the window/altitude effects.

Q: The 9k struggles only at 4–6 PM in August. Did I undersize?
A: Maybe not. That’s likely solar + internal gains at peak. Try a pre-cool schedule (start earlier), and add shading. If nighttime/sleep comfort is great, your sizing is probably right.

Q: Can two small heads beat one big one?
A: Often yes—if they’re mapped to how the space is used. Modulation + zoning can beat a big single head that cools empty rooms and short-cycles.


🧩 28) My Sizing Checklist (Print-Friendly)

  • Measure each room/zone (ft²) with a laser.

  • Note ceiling height; compute CF = height / 8.

  • Label orientation and glass (N/E/S/W; big/small).

  • Pick starting load factor (25, 30, or 35 BTU/ft²).

  • Apply climate factor (0.9–1.2) from local experience/climate data.

  • Add occupancy and appliance gains for peak times.

  • Compare totals to available head sizes (9k/12k/18k/24k…).

  • Prefer modulation & run time over max BTU ego.

  • Validate with sensors: keep RH 40–50%, long quiet cycles.

  • Save a one-page calc summary for rebates/records.


🌎 29) Environmental & Cost Wins (Why I Care)

Right-sized equipment runs less and runs smarter. According to the DOE, every kWh avoided saves about 0.9 lb of CO₂ in many U.S. grids. A typical oversize mistake can burn 150–300 kWh more each cooling season. Do the math: that’s 135–270 lb CO₂ avoided… from sizing correctly.

It also sounds better. A quiet system you forget about is the dream.


🔧 30) Installation Notes That Protect Your Sizing Wins

I won’t re-hash the whole install guide, but these have huge performance impact:

  • Line-set lengths, bends, and elevation within spec—check the manual.

  • Flare, torque, and vacuum: pull a deep vacuum (<500 microns) and confirm it holds.

  • Condensate management: slope and trap properly to avoid water re-evap affecting RH.

  • Head placement: don’t tuck units into alcoves where they only “see” a small air pocket.

Sizing is step 1. Installation quality is step 1A. The best math can’t outrun a bad vacuum or a kinked line set.


🧠 31) Final Takeaways (Mike’s Short Version)

  • Don’t size to house sq ft; size to how rooms behave.

  • Square footage start, then correct for volume, climate, glass, people.

  • Favor long, low-speed modulation for humidity control.

  • Validate with sensors; adjust schedules and airflow before changing hardware.

  • Keep your calc notes—they unlock rebates and help the next homeowner, too.


🛒 CTA: Ready to Map Your Own 2-Zone?

If your math looks like mine—one sun-exposed living area plus a smaller bedroom/office—this setup has been a sweet spot:

👉 MRCOOL DIY 5th-Gen 27,000 BTU 2-Zone (9k + 18k) at The Furnace Outlet