Service Life & Lifecycle Economics (When Age Stops Making Sense)
Typical lifespans are reliable starting points: furnaces 15–20 years, AC 10–15 years. Beyond these windows, efficiency drops, failures spike, and parts availability tightens. A simple lifecycle test:
Visual — Decision Timeline
Install ──────────10y─────────15y─────────20y
Normal AC: Replace Furnace: Replace Window
If a core component (heat exchanger, compressor, ECM blower) fails after the window, replacement usually beats repair. Heat exchanger cracks and compressor short-to-ground are “end-of-life” indicators.
Check model refrigerant and burner technology. Older R-22/R-410A AC or single-stage 70–80% AFUE furnaces rarely justify big repairs late in life. Start scoping modern options like R-32 condensers, R-32 packaged systems, or higher-AFUE furnaces under Furnaces. For space-constrained jobs, compare package units.
Rising Energy Bills: Quantify Degradation, Not Just “Feels Higher”
Bills creep up as heat exchangers foul, blower curves drift, and coils load with biofilm. Normalize osts to weather:
Visual — Normalized Energy Spend
Normalized kWh or Therms = (Utility Use) ÷ (CDD or HDD)
Trend 12–24 months
If normalized use rises >10–15% with no lifestyle or envelope change—and maintenance is current efficiency loss is baked into the equipment. Compare nameplate vs delivered performance:
-
Furnace: AFUE vs measured stack loss & ΔT (35–65°F typical)
-
AC: Rated SEER2/EER2 vs measured subcool/superheat, SHR, and coil ΔT
Log static pressure and compression ratios during spring/fall PMs. When you see persistent high static (>0.8 in.w.c. on many PSC/ECM air handlers) and elevated head pressures at design days, budget for replacement.
Explore R-32 AC + coils or packaged upgrades that reset the efficiency baseline.
Repair Frequency & the 50% Rule (What Pros Actually Use)
Add last 24 months’ repair spend to the quoted repair—then compare to 50% of installed-cost for a replacement. If Repairs ≥ 50% of Replacement, replace. This reflects downtime risk, trip charges, and lost efficiency.
Visual — Quick Cost Screen
Scenario |
Recent Repairs |
Current Quote |
Replacement |
Decision |
Aging furnace (18y) heat exchanger crack |
$650 |
$1,800 |
$4,800 |
Replace |
AC (14y) leaking coil + TXV |
$900 |
$1,200 |
$5,600 |
Replace |
ECM blower (7y) under warranty |
$0 |
$600 |
$5,000 |
Repair |
Include soft costs—no-cool callbacks, overtime, and lead times for obsolete parts. If lead time >7–10 days in peak season, advise replacement now to avoid emergency pricing. When you do replace, check line sets and accessories (filter racks, pads, disconnects) under Accessories.
Comfort Gaps: Uneven Rooms, Short Cycling, or “Runs Forever”
Under- or over-sized equipment, coil fouling, or duct issues show up as continuous running, short cycles, or 3–6°F room swings. Before condemning the unit, verify the air side:
-
External static vs blower table
-
Supply/return ΔT (heat: 35–65°F, cool: ~16–22°F typical)
-
Duct leakage and blocked returns
Visual — Airflow Triangle
Load (Manual J)
▲
Ducts (Manual D) ◀──▶ Blower (CFM @ ESP)
If equipment is old and the distribution is marginal, replacement with right-sized, better-turndown systems is the upgrade path. Consider variable-speed furnaces and R-32 AC + gas furnace combos or high-turndown ductless mini-splits for problem zones. For layout constraints, check ceiling cassette or concealed duct heads.
Noises & Odors That Mean “Stop and Inspect”
Banging/booming on furnace light-off suggests delayed ignition; screeching points to bearings or belt; rattling to loose panels or heat exchanger issues. On AC, grinding or humming + high amp draw can indicate compressor or fan motor failure. Odors matter:
-
Burnt electrical: motor windings or board traces
-
Musty: wet coils/drain issues; mold risk
-
Fuel smell: leak or incomplete combustion
A yellow/rolling furnace flame flags possible CO risk. Shut down and evaluate immediately.
When noises coincide with age window or known refrigerant (R-22/R-410A), price a replacement alongside repair. It’s straightforward to transition to R-32 air conditioners + air handlers with proper commissioning and a cleaned or replaced line set.
Safety First: CO, Electrical, and Indoor Air Quality Risks
Aging exchangers can crack, spilling combustion byproducts. Blue, stable flame is normal; yellow, dancing flame demands immediate testing (combustion analysis, draft, CO). Never ignore nuisance trips on rollout, pressure, or limit switches.
Electrical risks increase with heat-soaked boards and brittle wiring. On cooling, refrigerant exposure and oil staining at joints indicate leaks; condensate overflows can create microbial growth.
Action Path: If safety trips or CO alarms occur and the unit is near/over its service life, replacement is the risk-controlled route. Review options in Furnaces and Packaged Systems. For help triaging a hazard, see our Help Center or request a Quote by Photo to prioritize safe next steps.
Refrigerant Realities: R-22/R-410A Phase-Out vs R-32/R-454B
Many older systems still run R-22 (obsolete) or R-410A (being phased down). As supplies tighten, repair costs climb and environmental compliance gets stricter. New equipment increasingly uses R-32 or R-454B, with lower GWP and strong efficiency potential when paired with modern coils and expansion hardware.
Visual — Refrigerant Transition
Legacy → Transitioning → Current Choices
R-22/R-410A R-410A (phasing) R-32 / R-454B
If your system leaks or needs a major refrigerant-side repair and it’s >10–12 years old, replacing with an R-32 platform typically saves money long-term. Explore R-32 condensers, R-32 AC + coils, and R-32 heat pump systems.
Leaks, Moisture, and Drainage: Protect the Building, Not Just the Unit
Water on the floor or rust in the pan is never “just condensate.” Check traps, pitch, and secondary drains. Wet insulation or musty odors signal microbial growth—an IAQ issue and a potential liability. Oil-stained fittings and low charge point to refrigerant leaks; use nitrogen pressure testing and electronic detection instead of relying on dyes long-term.
Visual — Condensate & Leak Checklist
□ Clear P-trap □ 3/4" line pitched 1/8" per ft
□ Float/overflow switch tested
□ Pan integrity □ Insulation dry □ No oil stains
If the system is old and repeatedly leaking, upgrade to sealed, cleanable coil designs and reliable drain safeties. Consider accessories (float switches, pans) during replacement. For room-by-room solutions where drains are challenging, evaluate through-the-wall units or ductless mini-splits.
Right-Sizing & System Architecture: Get the Design Right Now
Replacement is the perfect moment to fix sizing and distribution. Run or verify Manual J load, confirm CFM needs (≈400 CFM/ton cooling baseline), and validate ducts for ESP ≤ equipment rating. Poor ducts + new equipment still equals poor comfort.
Architecture Options:
-
Gas furnace + R-32 AC for cold-dominant climates.
-
Heat pump (R-32/R-454B) with electric backup for mild winters.
-
Ductless for additions, hot rooms, or retrofit constraints—see wall-mounted.
-
Packaged units for rooftops or tight mechanical rooms: residential packaged.
Use our Sizing Guide and optional Design Center to spec correctly the first time.
Total Cost of Ownership, Payback & How to Budget It
Don’t chase the lowest install ticket; chase lowest 10-year cost. Add: equipment + install + expected maintenance + energy + probable repairs − incentives.
Visual — Simple Payback
Payback (years) = (Installed Cost Difference) ÷ (Annual Energy Savings)
Variable-speed furnaces and high-SEER2 heat pumps typically cut shoulder-season costs and improve SHR/comfort. If cash flow matters, see HVAC Financing. Protect the investment with the Lowest Price Guarantee and our Satisfaction Policy. For quick scoping, use Quote by Photo and include nameplate photos, filter size, duct dimensions, and any hot/cold rooms.
When “Repair” Is Still the Right Call (And How to Decide Fast)
If the unit is young, parts are in-warranty, and the failure is non-catastrophic (pressure switch, igniter, capacitor, single control board trace), it’s usually repair. Confirm there’s no underlying air-side or refrigerant-side issue causing repeat failures (high static, low airflow, slugging, non-condensables).
Rapid Triage Flow:
-
Under service-life window? → Repair unless core component failed.
-
Over window + expensive part? → Replace.
-
Safety trip or CO risk? → Replace after hazard mitigation.
-
Refrigerant obsolete + major leak? → Replace.
When repair wins, consider targeted upgrades (ECM blower, better filtration, drain safeties) from Accessories. If a zone or addition needs help, add a room AC or window unit to avoid over-sizing the main system.