Key Takeaways

  • PTACs must meet size-based EER rules (≥11.9 for <7,000 Btu/h)

  • Federal law sets standards; states can require more

  • Canada uses different rules—check labels

  • ENERGY STAR models cut energy use by 10–15%

Why PTAC Regulations Matter in 2025

Modern PTAC unit installed in hotel room showcasing comfort and compliance with 2025 HVAC energy regulations.Hotel owners, apartment managers, and even sunroom DIY‑ers love Packaged Terminal Air Conditioners (PTACs) because they slide neatly through an exterior wall. But that convenience can hide a big risk: buying a model that guzzles electricity or, worse, ignores modern safety codes. In the last decade, the U.S. Department of Energy (DOE) and Natural Resources Canada (NRCan) have tightened the rules, pushing manufacturers to design cleaner, safer machines. This article breaks down those rules in plain English. You’ll learn the exact efficiency numbers a PTAC needs to hit, what the law says about safe installation, and how to spot a unit that truly meets 2025 standards—not just marketing claims. 

Need a compliant, high-efficiency PTAC for 2025? Browse R-32 PTAC units.

Minimum Energy Efficiency Rules for PTAC Units

Close-up of PTAC EnergyGuide label with emphasis on efficiency compliance in a clean home setting.Every PTAC sold in the U.S. carries a yellow EnergyGuide label. The most important line on that sticker is the Energy Efficiency Ratio (EER)—cooling output divided by the electricity it consumes. The DOE’s 2017 update set these floor values for standard‑size PTACs:

  • < 7,000 Btu/h: 11.9 EER

  • 7,000 – 15,000 Btu/h: 14  – (0.3 × capacity in 1000 Btu/h)

  • > 15,000 Btu/h: 9.5 EER

Packaged Terminal Heat Pumps (PTHPs) must also hit minimum Coefficient of Performance (COP) numbers when heating. These thresholds ensure that a room unit won’t quietly eat through kilowatt‑hours all summer. If you see a PTAC with an EER notably above the floor—say 12.5 for a 6,800 Btu/h model—it may qualify for ENERGY STAR, translating into extra savings. 

For upkeep pointers that keep real‑world efficiency high, bookmark our PTAC maintenance tips.

Understanding EER and COP Numbers Without the Math Headache

nfographic-style visual of PTAC unit with simplified EER and COP energy performance icons.Think of EER like miles‑per‑gallon for cooling: higher is better. A jump from 10 to 12 EER slices cooling costs by roughly 17 %. COP applies to heating: it compares heat moved indoors to the electricity used. A COP of 3 means every dollar of electricity gives you three dollars’ worth of heat. These ratios are measured in a lab using DOE’s uniform test method (10 CFR 431.96) so brands have to play by the same rules

You’ll also see SEER and HSPF on split systems, but PTACs stick with EER and COP because they operate at a single indoor temperature.

U.S. Federal Standards: 10 CFR Part 431 Explained

v: Know Federal HVAC Standards
Alt Text: Facility manager reviewing HVAC compliance paperwork next to PTAC unit under U.S. regulations.Under the Energy Policy and Conservation Act (EPCA), the DOE writes legally binding standards for commercial HVAC gear. Subpart F of 10 CFR Part 431 covers PTACs and PTHPs, spelling out:

  1. Test procedureshow labs must measure EER and COP.

  2. Certification rulesmanufacturers must submit data yearly and keep records.

  3. Enforcementthe DOE can fine makers up to $503 per unit for false ratings.

Because these are federal rules, individual states generally can’t set weaker limits. They can, however, ask for tougher ones if energy savings justify it, which California often does. Facility managers who buy in bulk should ensure purchase orders reference the latest federal tables to avoid costly returns. For a 60‑second primer, scroll through our HVAC Tips Blog.

Canadian Requirements: CAN/CSA‑C744‑17 at a Glance

Follow Canadian PTAC Standards
Alt Text: PTAC inspection scene at U.S.–Canada border with flags and a certified label indicating compliance.If your property straddles the U.S.–Canada border or imports equipment northward, you must know CAN/CSA‑C744‑17. This standard mirrors U.S. EER levels but adds Canadian test tweaks such as different supply voltages and an insulation‑effectiveness check. Provinces may tack on additional regulations; British Columbia, for instance, sets stricter winter performance to protect against cold snaps. NRCan enforces the rules at customs, so mislabeled PTACs can get turned away at the border. Manufacturers often stamp “C744‑17 Certified” right on the nameplate.

Want all-season performance? Shop PTAC heat pump models.

Safety Standards: Refrigerants and Proper Wall Installation

PTAC unit being tested in a clean HVAC certification lab with DOE and ENERGY STAR references.Efficiency means nothing if the unit isn’t safe. Modern PTACs use R‑410A or eco‑friendlier R‑32 refrigerants, which operate at higher pressures than old R‑22. That’s why technicians must use gauges rated for the correct refrigerant to avoid hose bursts. Electrical safety matters too: 265‑volt PTACs need dedicated breakers, while 208/230‑volt models often share circuits. Wall sleeves must be sealed with fire‑rated foam to block exhaust gases and moisture. Many hotel fires start when lint builds up in the interior grille; a quarterly vacuum session is quicker than a call to the fire marshal. For real‑world sizing stories, explore our PTAC sizing guide.

Certification Paths: From DOE Compliance to ENERGY STAR

Technician highlights mismatched HVAC wall sleeves and voltage issues in hotel supply room.Step 1: DOE certification. Manufacturers submit a sample batch to a third‑party lab. Results feed into the DOE CCMS database.
Step 2: AHRI Performance Verification. Random market pulls keep brands honest year‑round.
Step 3: ENERGY STAR qualification. A model that beats federal minimums by ~10 % (exact number varies by capacity) earns the blue label. ENERGY STAR also requires sound‑level limits—music to hotel guests’ ears. End users should request a Certificate of Compliance with each shipment; it’s free and proves the unit’s legal status.

Looking for simple wall-mounted options? Compare through-the-wall AC units

Common Compliance Pitfalls (and How to Avoid Them)

HVAC installer reviewing energy upgrade plans at hotel site with R-32 refrigerant and EER trends.

  • Buying surplus stock built before the 2017 rule—often cheap online but illegal to resell.

  • Mix‑matched wall sleeves that restrict airflow, tanking the tested EER by up to 20 %.

  • Wrong voltage selection (115 V vs 230 V) leading to tripped breakers and warranty voids.

  • Skipping record‑keeping. Hotels over 10 units must keep purchase invoices for five years in case the DOE audits.

Solution? Work with distributors who supply the latest certificates and sleeves rated for your brand. 

Installing new units in multi-zone buildings? Explore R32 gas heater combos.

Future Trends: How Upcoming Rules Could Affect PTAC Buyers

HVAC technician inspects PTAC unit with R-410A gauges and fire-rated foam sealant in hotel room.

Let me know when you're ready for the next image!

The DOE reviews PTAC standards roughly every six years. A draft proposal released in early 2024 explores bumping the < 7,000 Btu/h threshold from 11.9 to 12.5 EER and phasing out R‑410A for lower‑GWP refrigerants like R‑32 by 2027. If adopted, manufacturers will redesign compressors and heat‑exchanger fins—raising prices 5‑10 % initially but promising 15 % lower energy bills. Building owners planning multi‑year renovations may want to install today’s high‑EER, R‑32 PTACs to stay ahead of the curve. 

Need certified sleeves and install parts? Browse PTAC accessories.

Frequently Asked Questions

Q1. Do PTAC regulations apply to used units?
Yes. Selling or installing a used PTAC that doesn’t meet the current standard is illegal in most U.S. states.

Q2. How do I find the EER on an older PTAC?
Check the metal data plate on the chassis. If only watts and Btu/h are listed, divide Btu/h by watts to estimate EER.

Q3. Is ENERGY STAR mandatory?
No, but many hotel chains require it for brand compliance.

Q4. Can I install a PTAC myself?
You can slide it into a pre‑built sleeve, but electrical wiring and refrigerant service should be done by a licensed HVAC pro.

Q5. Will upcoming refrigerant changes make my current PTAC obsolete?
No. Existing R‑410A units can be serviced throughout their lifespan; the phase‑down only affects new manufacturing after the deadline.