Key Takeaways
-
Don’t oversize: Too much BTU leads to humidity, waste, and wear.
-
Know the role: PTACs cool and heat—they’re not air purifiers or dehumidifiers.
-
Match the load: Size by room BTUs and power supply for proper performance.
-
Maintain it: Clean coils, replace filters, and check it twice a year.
-
Fix mould right: Use real ventilation or a dehumidifier—not a bigger unit.
PTAC Myths Still Trip Up U.S. Owners
About one‐third of American hotels and countless apartments rely on packaged terminal air conditioners (PTACs).¹ Yet many owners still choose the wrong size, skip maintenance, or expect the unit to solve humidity problems by itself. These slip-ups raise power bills by 20 % or more and leave rooms with sticky or drafty issues that are gaining attention as 2025 energy rules push for tighter performance. This guide clears up five stubborn myths, shows why they matter, and shares simple, expert-level fixes any property manager or homeowner can follow. By the end, you’ll know how to spec, wire, and care for a PTAC so it keeps its promise: quiet comfort at the lowest possible cost.
Use our PTAC sizing guide to pick the right BTU model.
Myth 1: “Bigger PTAC Units Are More Efficient”
A larger unit blasts cold or warm air faster, but that’s exactly the problem. Oversized PTACs hit the set point in minutes, shut off, then restart again and again. Each short cycle:
-
Fails to remove much moisture, so the room feels clammy.
-
Uses up to 15 % extra electricity from repeated compressor starts.
-
Causes extra wear on relays and the scroll compressor.
Proper sizing starts with square footage and climate zone. Use a reputable chart—like this PTAC sizing guide for a quick BTU check—or ask an HVAC pro for a Manual J calculation. Remember: the right capacity, not the biggest, runs longer, steadier cycles that dry the air, trim bills, and keep parts happy.
Myth 2: “PTAC Units Get Rid of Mould”
Mould thrives when relative humidity stays above 60 %. A PTAC’s cooling cycle removes some water vapour, but only while the compressor runs. If the unit is oversized—or if outdoor air leaks in—run-time drops and moisture bounces back. Worse, many PTACs have no dedicated dehumidification mode. Relying on them alone can raise mould risk in warm, damp regions like the Gulf Coast. Pair the unit with tight building seals, bathroom exhaust fans, and when humidity spikes, a stand-alone dehumidifier. For more moisture-control ideas, see our indoor air quality basics article.
Myth 3: “Any Electrical Circuit Will Do”
A 15,000 BTU PTAC can draw 12–20 amps at full load. Plugging it into a 15-amp circuit or mismatching the voltage (208 V unit on 240 V supply) can cause dim lights, tripped breakers, and slower fan speed—symptoms many mistake for a “bad” unit. Always match:
-
Voltage (120 V, 208/230 V, or 265 V).
-
Amperage rating of the receptacle and breaker.
-
NEMA plug type to avoid unsafe adapters.
If you’re swapping an old unit for a high-efficiency model, have an electrician verify wire size before you buy. Correct power equals correct capacity and a longer compressor life.
Find energy-efficient PTAC systems that align with 2025 rebate-ready specs.
Myth 4: “PTACs Supply Enough Fresh Air and Positive Pressure”
Most PTACs have one small slide that mixes a trickle of outdoor air when the fan runs. This flow—often <20 cfm—falls far below ASHRAE 62.1 ventilation codes. Wind gusts can also reverse the flow, sucking humid air indoors. Relying on PTACs for pressurisation leads to musty odours, drywall moisture, and even door-frame rust in coastal hotels. Buildings still need operable windows, energy-recovery ventilators, or dedicated make-up air systems to keep rooms healthy and dry.
Myth 5: “Only Fix a PTAC After It Breaks”
Just because a PTAC sits in a wall sleeve doesn’t mean it’s maintenance-free. Dusty coils cut efficiency by 5 % after a single season. A clogged filter can slash airflow in half, forcing the compressor to overheat. Preventive care is simple:
-
Monthly: vacuum or rinse the filter.
-
Seasonally: flush the condensate pan, check the seal gasket, and test the heating strip.
-
Yearly: deep-clean the coil and blower wheel, tighten electrical lugs.
Need a plan? Follow this maintenance checklist or bookmark our HVAC Tips hub. A well-kept PTAC can last 12–15 years, double the life of a neglected one.
How These Myths Drain Comfort and Cash
Combine the myths and you get a perfect storm: oversized, under-ventilated rooms that feel sticky, smell musty, and guzzle electricity. Short-cycling alone can tack $150-$250 onto an annual utility bill per unit. Add the cost of premature compressor failure (~$450) and drywall repairs from hidden mould, and the price of bad information skyrockets. On the flip side, right-sizing and routine service often pay back in one cooling season. That’s why many utility rebate programs in 2025 now ask for proof of proper load calculation and maintenance logs before issuing checks.
Save more in 2025 explore rebate-eligible PTACs designed to meet new DOE standards.
Expert Tips: Choose, Install, and Maintain a PTAC the Smart Way
-
Measure twice, buy once. Use this room-by-room sizing guide to lock in the correct BTU range.
-
Match power. Verify breaker size, wire gauge, and plug type before ordering.
-
Seal the sleeve. A pea-sized gap invites rain and pests; use closed-cell foam.
-
Add fresh-air support. A low-energy ERV pairs well with PTACs in humid states.
Following these steps keeps rooms comfortable, meets today’s stricter energy codes, and protects your budget
Ready to upgrade? Shop PTACs built for 2025 standards.
Frequently Asked Questions
Q 1. How often should I change a PTAC filter?
Every 30 days in summer, 60 days in mild weather.
Q 2. Can I install a PTAC myself?
You can slide the chassis in, but wiring and dedicated circuits should be handled by a licensed electrician.
Q 3. Does a PTAC always need a drain line?
Most units use an internal slinger ring to evaporate condensate; very humid zones may add an external drain.
Q 4. What’s the best thermostat setting for saving energy?
Set cooling to 78 °F and heating to 68 °F when occupied; raise or lower by 4 °F when away.
Q 5. How long does a well-maintained PTAC last?
Typically 12–15 years, sometimes longer in mild climates.