When homeowners reach out with concerns like furnace not heating, home heater not working, or heat not working furnace, the frustration is always the same. You turn the thermostat up, expect warm air, and instead get lukewarm airflow—or nothing at all. These situations are stressful, especially in colder months, and they often raise bigger questions about whether the furnace is failing, undersized, or simply misunderstood.
As someone who spends a great deal of time explaining electric heating systems to homeowners, I’ve found that many of these concerns stem from confusion about how electric furnaces operate. The Goodman MBVK electric furnace is a strong example of modern electric heat design—reliable, straightforward, and safe—but it behaves differently than gas-fired systems. When expectations don’t align with operation, it can feel like something is wrong when the system is actually doing exactly what it was designed to do.
This article walks through why an electric furnace may not be heating properly, what “not heating enough” really means in practical terms, and how to evaluate performance using the Goodman MBVK as our reference point.
What “Furnace Not Heating” Really Means in an Electric System
When homeowners say their furnace is not heating, that statement can mean several different things:
-
The furnace runs, but the air feels cool
-
The system cycles on and off too frequently
-
The blower runs constantly with no noticeable heat
-
Some rooms are warm while others remain cold
-
The furnace never reaches the thermostat setpoint
In electric systems like the Goodman MBVK, these symptoms rarely point to combustion failures or fuel issues. Instead, they typically relate to airflow, sequencing, electrical supply, or thermostat configuration.
Unlike gas furnaces that produce very hot air quickly, electric furnaces generate heat through resistance-based heating elements. The result is steadier, quieter operation—but with lower discharge temperatures that can be misinterpreted as insufficient heat.
How the Goodman MBVK Electric Furnace Produces Heat
The Goodman MBVK is an electric air handler-style furnace that uses electric heat strips to warm air as it passes through the system. These heat strips are staged using sequencers, which activate heating elements gradually to prevent electrical overload and maintain comfort consistency.
Instead of a single ignition event, the MBVK operates in controlled steps:
-
Thermostat calls for heat
-
Blower motor begins airflow
-
First heat strip energizes
-
Additional strips engage as demand increases
-
Sequencers shut down heat in reverse order when satisfied
This design prioritizes safety, efficiency, and component longevity, but it also changes how heat feels at the registers—especially to homeowners accustomed to gas furnaces.
Why the Air May Feel Cool Even When the Furnace Is Working
One of the most common reasons people report heat not working furnace is because electric heat feels different. Gas furnaces often discharge air between 120–140°F. Electric furnaces typically deliver air closer to 90–105°F.
That air is still warmer than room temperature, but because it’s moving continuously, it may feel cooler to the skin. This does not mean the furnace is failing.
According to general HVAC performance guidance published by the U.S. Department of Energy, consistent airflow at moderate temperatures is a normal characteristic of electric heating systems .
Thermostat Configuration: A Leading Cause of “Home Heater Not Working”
Thermostat settings are one of the most overlooked contributors to electric heating complaints. With the Goodman MBVK, thermostat compatibility and configuration matter.
Common thermostat-related issues include:
-
Heat pump mode enabled when no heat pump is installed
-
Incorrect staging setup for auxiliary heat
-
Anticipator or cycle rate mismatches
-
Thermostat location exposed to drafts or sunlight
Electric furnaces rely on accurate demand signals. If the thermostat is misconfigured, the furnace may never bring all heating elements online, leading to complaints that the furnace is not heating enough.
Electrical Supply Problems That Limit Heating Output
Electric furnaces require adequate electrical capacity to perform properly. The Goodman MBVK is designed to operate with specific breaker sizes depending on installed heat strip capacity.
If electrical issues exist, the furnace may:
-
Run only partial heat stages
-
Trip breakers intermittently
-
Cycle heat strips off prematurely
-
Operate blower-only with no heat
The importance of proper electrical design in electric heating systems is well documented in electrical safety standards published by organizations such as the National Fire Protection Association.
A furnace that appears to be running but not heating enough may simply not be receiving sufficient electrical input to energize all heating elements.
Airflow Problems That Mimic Heating Failure
Airflow is just as important as heat generation. The Goodman MBVK depends on unrestricted airflow to transfer heat efficiently.
Common airflow problems include:
-
Dirty or restrictive air filters
-
Undersized ductwork
-
Closed or blocked supply registers
-
Leaking return ducts
-
Improper blower speed settings
When airflow is compromised, safety limits may prevent heat strips from fully energizing. This protective behavior can feel like the furnace is underperforming, when it is actually preventing overheating.
ASHRAE airflow standards emphasize the importance of proper air volume for electric heating performance .
Why “Furnace Not Heating Enough” Is Often a Sizing Issue
Electric furnaces are extremely sensitive to sizing accuracy. The Goodman MBVK is available in multiple configurations, but if the installed heat strip capacity does not match the home’s heat loss, the system will struggle during colder conditions.
Signs of undersizing include:
-
Furnace runs continuously but never reaches set temperature
-
Heat output feels consistent but insufficient
-
Performance worsens during extreme cold
-
No mechanical or electrical faults found
Unlike gas furnaces, electric systems cannot “overfire” to compensate. They deliver exactly the heat they are designed for—no more, no less.
Outdoor Temperature and Electric Heat Performance
Electric resistance heat performs consistently regardless of outdoor temperature, but the perceived effectiveness changes as heat loss increases.
In very cold weather:
-
Walls and windows lose heat faster
-
Floors and surfaces remain cooler
-
Air stratification increases
-
Heating cycles lengthen
This can create the impression that the furnace is not heating, even though it is operating at full capacity.
Energy performance data from the U.S. Energy Information Administration highlights how building envelope efficiency plays a major role in electric heating satisfaction .
The Role of Auxiliary and Emergency Heat Settings
If the Goodman MBVK is paired with a heat pump, auxiliary heat settings become critical. Improper configuration can cause the system to rely too heavily on the heat pump—or lock out electric heat entirely.
This often leads to complaints such as:
-
Heat runs but never warms the home
-
Furnace only produces lukewarm air
-
Home heater not working during cold snaps
Correct staging ensures electric heat supplements or replaces the heat pump when needed.
Maintenance Factors That Affect Heating Output
While electric furnaces require less maintenance than gas systems, they are not maintenance-free.
Important maintenance items include:
-
Annual inspection of heat strips
-
Verification of sequencer timing
-
Blower motor lubrication (if applicable)
-
Electrical connection tightening
-
Filter replacement schedules
Neglected maintenance can lead to reduced output, shortened component life, and ongoing complaints about insufficient heating.
When a Furnace Truly Is Not Heating
Although many heating complaints are perception-based, there are times when a furnace genuinely is not producing heat.
True failure indicators include:
-
No temperature rise at supply vents
-
No amperage draw on heat circuits
-
Burnt or failed heating elements
-
Faulty sequencers or relays
-
Tripped high-limit switches that will not reset
In these cases, professional diagnosis is essential. Electric furnaces operate at high voltage, and improper troubleshooting can pose safety risks.
Why the Goodman MBVK Remains a Reliable Electric Heating Solution
Despite the misconceptions surrounding electric heat, the Goodman MBVK electric furnace remains a dependable option for homes without gas service, all-electric builds, and heat pump applications.
Its strengths include:
-
Simple, combustion-free design
-
Quiet, steady operation
-
Compatibility with modern thermostats
-
Modular heat strip staging
-
Reduced maintenance requirements
When installed and configured correctly, the MBVK delivers consistent comfort—even if it feels different than traditional gas systems.
Final Thoughts: Reframing “Heat Not Working Furnace” Complaints
When homeowners say their furnace is not heating or their home heater is not working, the solution is rarely panic or immediate replacement. In electric systems like the Goodman MBVK, understanding how heat is generated, delivered, and controlled makes all the difference.
Electric heat is steady, predictable, and safe—but it requires realistic expectations, proper sizing, and correct setup. Once those elements are aligned, most complaints about insufficient heat disappear.
If your furnace truly isn’t heating, professional evaluation is the right next step. But if it’s running, moving air, and maintaining temperature slowly but steadily, there’s a good chance it’s doing exactly what it was designed to do.