Let’s Talk, DIYers — Jake Here 👋

Alright. So you picked up an 80,000 BTU R-32 gas furnace, maybe you watched a few YouTube videos, and now you’re thinking — “I got this.” Respect. I love a motivated DIYer. But here’s what I don’t love: the callback. The email. The “Hey Jake, can you come look at this real quick?” And I show up to find melted wiring, a vent pipe aimed at a wall, or a gas line held together with teflon and hope.

So I wrote this for you — the smart, hands-on homeowner who wants to get it right but maybe doesn’t know what not to do yet. We’re gonna walk through the top 7 mistakes I’ve seen time and time again. These aren’t guesses — they’re field-proven disasters. Avoid these, and you’ll be in good shape.

 

1. Skipping the Load Calc and Guessing Furnace Size 📏

Look — square footage matters, but it’s just the start. I’ve seen people throw an 80,000 BTU furnace into a 1,300 sq ft house thinking “more heat = more comfort.” What they get instead? Short cycles, wild temp swings, and a cracked heat exchanger in two years.

You need a Manual J calculation — insulation, window quality, air leaks, ceiling height, all of it matters. Guessing leads to oversizing. Oversizing leads to breakdowns.

The folks over at HVAC.com explain furnace sizing better than most. Read it. Then run your numbers, not your gut.

 

2. DIY Venting That’ll Land You on the News 💨🧨

I hate to say it, but venting errors can get people hurt. R-32 systems require airtight PVC or CPVC venting. You need slope, separation from intakes, and clearance from combustibles.

Here’s what I’ve seen:

  • Vents piped uphill (wrong slope)

  • Exhaust dumping right under a bedroom window

  • Intake and exhaust lines reversed (!)

  • No vent supports, so the whole pipe sags like overcooked spaghetti

Follow the installation manual to the letter. And if you need a visual walkthrough, Carrier has a great explainer on furnace venting.

Also, do not reuse old metal flues. R-32 systems are sealed combustion and have different venting requirements. That rusty galvanized pipe from the '90s has no place in your new install.

 

3. Setting the Furnace on a Tilt 🪜

You might not think a slightly uneven slab matters — but it does. Big time. I saw one install where condensate kept backing up into the secondary heat exchanger because the unit was pitched back toward the cabinet. Fried the control board in under six weeks.

Use a level. Shim it. Check it twice. Water flows downhill, and if you don’t give it the right path out, it’ll find one inside — through the electronics.

While you’re at it, make sure you’ve got:

  • A drain pan under the unit (especially in attics or closets)

  • Isolation pads to reduce vibration

  • 30 inches of clearance for access (yes, even if it “barely fits”)

 

4. Gas Lines Done With Guts Instead of Gauges 🔥

I respect DIYers, but messing with gas without the right tools is how homes blow up. R-32 furnaces use natural gas or LP, and they need exact manifold pressure. That means you test with a manometer — not a guess, and definitely not a match.

Want the official playbook? The NFPA 54 National Fuel Gas Code breaks it all down.

Quick checklist:

  • Use black iron or CSST (if code allows)

  • Add a sediment trap below the inlet

  • Test at 10 psi for 15 minutes minimum

  • Never skip the leak test

I once had a guy call me because his burners kept “sputtering.” His gas line had four 90-degree elbows in a row and no sediment trap. It was like feeding the furnace through a crazy straw.

 

5. Backwards Wiring and Missing Grounds ⚡

Polarity matters. I’ve seen reversed L1/L2 wiring cause igniter failure, weird board resets, and GFCIs tripping randomly. Furnace control boards aren’t forgiving — they need clean, stable power.

Check everything with a multimeter:

  • Hot-to-neutral should be 120V

  • Hot-to-ground should also be 120V

  • Ground-to-neutral should be zero

And run the furnace on a dedicated 15 or 20 amp circuit — no sharing with garage outlets or kitchen lights.

If you’re staring at the thermostat wiring and feel lost, HVAC School has simple thermostat wiring diagrams that’ll keep you on track.

Pro tip: label your wires before you disconnect them. Trust me, your future self will thank you.

 

6. Ugly or Useless Condensate Drains 💧

R-32 high-efficiency furnaces sweat — a lot. That condensate needs a drain line that’s:

  • Properly trapped

  • Primed before startup

  • Sloped at ¼ inch per foot

  • Supported every 3–4 feet

I once saw a drain line run uphill into a laundry tub. The homeowner thought the water would “just push through.” What happened? Furnace shut down every 3 days from a tripped pressure switch. Water backed up into the inducer.

If gravity won’t help, use a condensate pump. And always test your trap by pouring water through it before you fire up the system.

 

7. No Startup Testing — Just Crossed Fingers 🎲

Biggest mistake I see? Folks turning the furnace on and walking away without testing a single thing. That’s like starting a new car and hitting the highway without checking the brakes.

Here’s what you need to do every single time:

  • Measure static pressure with a manometer

  • Clock the gas meter (or test with your gauge)

  • Confirm blower speed and airflow

  • Verify flame signal (should read 2–6 µA steady)

  • Check for error codes during warmup and shutdown

Need a refresher on pressure testing? Behler-Young’s gas pressure tutorial is worth bookmarking.

Don't skip this. It’s how you catch the stuff that looks fine but isn’t — like reversed blower direction, blocked intake pipes, or high-limit switches tripping quietly in the background.

 

Final Take from Jake 👊

Look, I respect the hustle. You’re rolling up your sleeves and tackling something most people wouldn’t dare touch. But this isn’t a weekend IKEA build. An 80,000 BTU R-32 furnace is a precision machine — and if you make the wrong call, it can cost you more than just comfort.

Avoid these 7 mistakes and you’ll already be ahead of 80% of DIY installs I’ve seen. You don’t need to be perfect — you just need to be careful, thorough, and honest with yourself when it’s time to call in a pro.

If you're still shopping or just want to compare models, the team over at The Furnace Outlet has a whole collection of ready-to-ship, high-efficiency options. You can check out their R-32 Gas Furnaces – 80,000 BTUs collection here. It’s a solid lineup backed by warranties and specs that make sense.

Need more troubleshooting tips for your system? Visit my guide: Heat’s Out? A 101 Furnace Fix-It Guide for Your 80,000 BTU R-32 System.

So get after it — but keep your eyes open, your level handy, and your manometer ready.

See you in the field.
— Jake, your comfort loving tech

The comfort circuit with jake