Troubleshooting Guide What to Do If Your Amana PTAC Isn’t Heating or Cooling Properly

I’ll never forget the night I got a call from my cousin’s Airbnb guests: “The AC isn’t cooling—it’s 85 degrees inside!” At first, my heart sank. I thought, Oh no, the Amana PTAC must have broken down. But as it turned out, the issue was minor—a dirty filter. A quick cleaning, and the room cooled right back down.

The truth is, most PTAC (Packaged Terminal Air Conditioner) problems are small things you can check yourself before calling a technician. In this guide, I’ll walk you through a step-by-step troubleshooting process for the Amana 9,000 BTU PTAC with Heat Pump + 2.5 kW Backup Heat.


⚡ Step 1: Safety First

Before you do anything:

  • Turn off and unplug the unit.

  • If you smell burning, see sparks, or hear loud electrical buzzing, stop immediately and call a professional.

👉 Samantha’s tip: “I always keep a surge protector on my PTAC. It’s a cheap way to protect an expensive system.”

🔗 Reference: NFPA – Electrical Safety Tips.


❄️ Problem: PTAC Isn’t Cooling

If your Amana isn’t cooling the way it should, here’s what to check:

🔹 1. Dirty Filter

  • Remove and inspect the filter.

  • If it’s gray or clogged, airflow is restricted.

  • Fix: Clean or replace the filter.

🔹 2. Blocked Coils

  • Dust or dirt on the evaporator or condenser coils prevents heat transfer.

  • Fix: Vacuum or use a coil cleaner spray.

🔹 3. Airflow Obstruction

  • Curtains, furniture, or decor may block the front grille.

  • Fix: Move obstructions at least 2 feet away.

🔹 4. Wrong Settings

  • Make sure the unit is set to cooling mode with a temperature below the current room temp.

🔹 5. Low Refrigerant

  • If the air feels only slightly cool, refrigerant may be low.

  • Fix: Requires a licensed HVAC technician.

👉 Samantha’s story: “The Airbnb issue? A filter so caked in dust the poor unit couldn’t breathe. Lesson learned: monthly cleaning.”

🔗 Reference: Energy Star – Room AC Maintenance.


🔥 Problem: PTAC Isn’t Heating

Heating problems are especially common in cold weather.

🔹 1. Heat Pump Limits

  • Heat pumps don’t perform well below ~40°F.

  • Fix: Ensure the electric backup heat is working.

🔹 2. Backup Heat Not Engaging

  • Amana PTACs with 2.5 kW backup need the correct power cord and breaker size.

  • Fix: Check if the right cord kit is installed (15A, 20A, or 30A depending on model).

🔹 3. Dirty Filter Restricting Airflow

  • Same as cooling—clean or replace.

🔹 4. Incorrect Thermostat Setting

  • Verify the thermostat is set to heat and above the room temperature.

🔹 5. Electrical Issue

  • A tripped breaker or faulty wiring can prevent backup heat from turning on.

  • Fix: Reset breaker or call an electrician.

👉 Samantha’s note: “One chilly night, I thought the PTAC was failing. Turns out, the backup heat wasn’t kicking in because the wrong cord kit had been installed. Once corrected, it worked perfectly.”

🔗 Reference: Amana PTAC Cord Sizing Guide.


🛑 Problem: PTAC Won’t Turn On

If the unit is completely unresponsive:

  1. Check power supply – Is the unit plugged in? Is the breaker tripped?

  2. Inspect outlet – PTACs often use a dedicated 208/230V outlet.

  3. Check reset button – Some Amana models have internal reset switches.

👉 If none of these solve it, call a technician.

🔗 Reference: Energy.gov – Room Air Conditioners.


💧 Problem: PTAC Is Leaking Water

Water on the floor? Don’t panic.

  • Clogged drain line → Clear debris with warm water or a flexible brush.

  • Improper wall sleeve tilt → Sleeve should slope outward slightly.

  • High humidity → Excess condensation is normal in hot, humid climates.

👉 Samantha’s story: “We thought the PTAC was broken when we saw water on the floor. Nope—the drain hole was blocked with lint. Five minutes with a pipe cleaner fixed it.”

🔗 Reference: EPA – Mold Prevention & Moisture.


🔇 Problem: Strange Noises

  • Rattling → Loose screws or unlevel sleeve.

  • Buzzing → Electrical issue (call a pro).

  • Whistling → Air leaks around the sleeve.

Fix: Tighten screws, reseal edges, or call an HVAC tech if electrical.

🔗 Guide: ASHRAE HVAC Standards.


👃 Problem: Bad Odors

  • Musty smell → Dirty filter or clogged drain pan.

  • Burning smell → Dust burning off backup heater at first seasonal use (normal).

  • Persistent burning → Electrical issue (call a pro immediately).

Fix: Clean filter, drain, and coils. Run the fan-only mode to circulate air.


📋 When to Call a Professional

While most PTAC issues are DIY-friendly, call a pro if:

  • Refrigerant needs to be recharged.

  • Electrical wiring looks damaged.

  • Compressor or fan motor is broken.

  • Leaks persist after cleaning drains.

Typical service cost: $100–$250, depending on repair.

🔗 Reference: HVAC.com – PTAC Repair Costs.


✅ Samantha’s Troubleshooting Checklist

  1. Check filter first – 50% of issues start here.

  2. Verify thermostat settings.

  3. Inspect airflow (coils & grille).

  4. Look for leaks or blockages.

  5. Test backup heat separately.

  6. Call a pro only after basic checks.

👉 Samantha’s tip: “I keep a laminated troubleshooting guide in the utility closet. Guests know what to try first before calling me.”


📌 Key Takeaways

  • Most PTAC issues are minor—filters, coils, or settings.

  • Backup heat requires the right cord kit and breaker to function.

  • Water leaks are usually drain or tilt issues, not mechanical failures.

  • Preventative maintenance (filters + seasonal care) is the best troubleshooting tool.


In the next topic we will know more about: Cost Breakdown: How Much Does a 9,000 BTU PTAC with Heat Pump Really Cost?