Sizing Guide: Choosing the Right BTU for Through-the-Wall Heat Pumps

Sizing Guide: Choosing the Right BTU for Through-the-Wall Heat Pumps

When customers ask me, “What size through-the-wall heat pump do I need?” I, Jake, always answer the same way: Sizing is a formula, not a guess. The right BTU capacity can make the difference between perfect year-round comfort and a unit that struggles all season long. Whether you're outfitting an apartment, bedroom, garage, or small commercial space, the right BTU size is the foundation of an efficient installation. This guide breaks the entire process down scientifically—no fluff, no guessing, just real-world HVAC math. And don’t worry: I’ll include charts, climate adjustments, ceiling considerations, and examples that make sense for everyday homeowners and installers.

Through-the-wall heat pumps have become a go-to solution for spaces where ductwork is impossible or inefficient. Their flexibility, energy savings, and compact form mean they’re increasingly chosen over window units or bulky central systems. But even the best heat pump will underperform if the BTU rating is wrong. So let’s break the system down step by step, the Jake way—methodical, confident, and based on actual HVAC principles.


1. Why BTU Sizing Matters for Through-the-Wall Heat Pumps

BTU—British Thermal Unit—is the measurement of heating and cooling power. Think of BTUs as horsepower for climate control. When your BTU rating is correct:

  • The unit hits your temperature target efficiently

  • It cycles properly

  • It avoids unnecessary wear

  • Energy bills stay low

  • Comfort is consistent across the entire room

When you’re oversized or undersized, you pay more, get less, and shorten your heat pump’s life. We’ll get into those consequences later, but first, let’s figure out how BTU sizing truly works.

One of the most accurate baseline formulas recommended across the HVAC community—and supported by resources such as Energy Star with simple square footage. But we’re not stopping there. A real Jake sizing includes ceiling height, insulation level, sun exposure, climate zone, room type, occupancy load, windows, doors, and even appliance heat output.


2. The Core BTU Formula Jake Uses Every Time

Here is the foundational sizing formula used by seasoned HVAC pros:

BTUs required = Square Footage × 20 (baseline cooling factor)

This baseline assumes standard insulation, an 8-ft ceiling, and moderate climate. Heating requirements can exceed cooling needs in cold regions, which we’ll adjust for in the climate section.

For example:
A 350-sq-ft room × 20 = 7,000 BTUs baseline cooling.

But baseline is just the start. Through-the-wall units are often expected to operate year-round, and heat output must be equivalent to or greater than cooling needs, depending on the climate.


3. Jake’s Complete BTU Chart for Through-the-Wall Units

Below is a practical BTU sizing chart for standard 8-ft ceilings and average insulation:

Room Size (Sq Ft) Recommended BTU
100–200 sq ft 4,000–6,000 BTU
200–300 sq ft 6,000–8,000 BTU
300–400 sq ft 8,000–10,000 BTU
400–500 sq ft 10,000–12,000 BTU
500–700 sq ft 12,000–15,000 BTU
700–1,000 sq ft 15,000–18,000 BTU

These numbers line up with recommended guidelines from multiple industry standards, such as ASHRAE and HVAC manufacturer sizing references 


4. Climate Zone Adjustments (Critical for Heat Pumps)

Cooling and heating demands vary dramatically depending on where you live. A through-the-wall heat pump installed in Minnesota needs more heating BTUs than one in Georgia. Below is Jake’s climate adjustment chart for both heating and cooling.

4.1 Cooling Climate Adjustment

Use this when summers are significantly hotter or milder than average:

  • Hot Southern Zones (e.g., Texas, Florida): +10–20% BTU

  • Humid Zones: +10% BTU

  • Mild Coastal Zones (e.g., Pacific Coast): baseline is fine

  • Cool Northern Zones: baseline or -10%

Example:
A 400-sq-ft Florida room → baseline 8,000 BTU × +20% = 9,600 BTU minimum.

4.2 Heating Climate Adjustment (More Important for Heat Pumps)

For heating, BTU adjustment is essential. Referencing climate maps similar to those found on the U.S. Department of Energy site.

  • Zone 1–2 (Southern warm zones): baseline heating OK

  • Zone 3–4 (Midwestern/Coastal mixed): +15–25%

  • Zone 5–6 (Northern/cold): +25–40%

  • Zone 7 (Extreme cold): Heat pump must be rated for low-temp operation

If you’re in a cold zone, always check manufacturer low-ambient ratings—many manufacturers include low-temp specs similar to examples found here


5. Ceiling Height Adjustments

The baseline BTU chart assumes 8-foot ceilings. But many modern homes and commercial spaces have 9–12 ft ceilings, dramatically increasing the volume of air that must be heated/cooled.

Jake’s rule:

For every foot above 8 ft, add 10% BTU.

Example:
A 300-sq-ft room normally needs ~6,000 BTU.
With a 10-ft ceiling: add 20% → 7,200 BTU.

Extra height = extra energy = extra BTU. Simple HVAC math.


6. Insulation & Sun Exposure Adjustments

Poor insulation, old windows, and extreme sun exposure require more BTU power.

Add these adjustments:

  • Poor insulation: +15–30%

  • Above-average insulation (new builds): -10%

  • South/west-facing rooms with many windows: +10–20%

  • Shaded/north-facing rooms: baseline or -10%

It’s common for older apartments—especially pre-1990 builds—to require up to +25% because of leaky framing and unsealed wall penetrations. These details matter in heat pump sizing more than most installers admit.


7. Occupancy & Heat Load Adjustments

People produce heat—about 250 BTU per person in a room. Electronics and appliances increase load further.

Add BTUs if:

  • Regular occupancy is more than 2 people

  • The room has multiple computers, TVs, and equipment

  • The space contains heat-generating appliances (garages, workshops)

Example:
A home office with two gaming PCs → +1,000–2,000 BTU.

These adjustments follow guidance commonly seen in energy-efficiency audits like those referenced on Home Energy Saver resources


8. Consequences of Oversizing or Undersizing (Jake’s Straight Talk)

This is where most homeowners get burned. Oversizing and undersizing affect both cooling and heating performance—especially with heat pumps that depend on proper cycling.

8.1 If You Undersize

  • Constant running

  • Uneven temperatures

  • Fails to heat in winter

  • High energy bills

  • Shortened compressor life

  • Unit freezes in low temps

8.2 If You Oversize

  • Short-cycling (starts and stops continuously)

  • Poor humidity control

  • Premature system failure

  • Hot–cold swings

  • Wasted energy

A properly sized heat pump runs longer, quieter, and more consistently. Cycling is stabilizing, not wasteful. Oversizing does more harm than good.


9. Real-World Examples (Apartments, Bedrooms, Garages)

Jake doesn't talk theory—he shows you the math that homeowners and installers actually use.


9.1 Example 1: 1-Bedroom Apartment (550 sq ft)

Space: 550 sq ft
Ceilings: 8 ft
Climate: Mid-Atlantic (Zone 4)
Sun Exposure: Moderate
Insulation: Average

Step 1: 550 × 20 = 11,000 BTU
Step 2 (Climate +20%): 11,000 × 1.20 = 13,200 BTU

Final Recommendation: 12,000–15,000 BTU through-the-wall heat pump
This size properly handles both cooling and heating demands.


9.2 Example 2: Bedroom (180 sq ft)

Space: 180 sq ft
Climate: Mild (Pacific Coast)
Ceilings: 9 ft
Insulation: Good

Step 1: 180 × 20 = 3,600 BTU
Step 2 (Ceiling +10%): 3,600 × 1.10 = 3,960 BTU
Step 3 (Good insulation -10%): ~3,600 BTU

Final Recommendation: 4,000–5,000 BTU heat pump

If the bedroom gets afternoon sun, add 10%→ 4,400 BTU.


9.3 Example 3: Garage Workshop (400 sq ft)

Space: 400 sq ft
Climate: Cold (Zone 5)
Ceilings: 10 ft
Insulation: Poor
Equipment: Power tools + 2 people

Step 1: 400 × 20 = 8,000 BTU
Step 2 (Ceiling +20%): 8,000 × 1.20 = 9,600 BTU
Step 3 (Poor insulation +25%): 9,600 × 1.25 = 12,000 BTU
Step 4 (Occupancy + equipment +1,500 BTU): 13,500 BTU
Step 5 (Cold climate +30% heating adjustment):17,500 BTU

Final Recommendation: 15,000–18,000 BTU heat pump, low-ambient rated.

Garages need more power—don't skimp.


10. When to Move Up or Down a BTU Size

Choose the next size up when:

  • You’re in a hot southern climate

  • Ceilings are 9 ft or higher

  • Insulation is poor

  • The room has large windows

  • The heat pump will run year-round

Choose the next size down when:

  • The room is shaded

  • The climate is cool and dry

  • Insulation is excellent

  • The unit is for occasional use

Jake rule: If your calculations put you within 500 BTU of the next size, go up.


11. Matching BTUs to Energy Efficiency Ratings

Another overlooked factor is how BTU sizing interacts with the energy efficiency ratio (EER/SEER2) and heating seasonal performance factor (HSPF). High-efficiency models sometimes require slightly less BTU output to maintain comfort in moderate climates, while lower-efficiency models may need a bump in capacity.

To understand deeper EER/SEER/HSPF metrics, refer to energy standards similar to those discussed by Energy.gov


12. Through-the-Wall vs Mini-Split BTU Sizing Differences

While both system types use BTU metrics, wall units have fixed airflow directions and smaller heat exchangers. This means:

  • They require stricter adherence to BTU guidelines

  • They are less forgiving of oversizing

  • Climate adjustment matters more for heating capacity

Mini-splits have variable-speed compressors that adapt to demand; through-the-wall systems don't. That’s why Jake’s method is precise—it keeps these limitations in mind.


13. Common Sizing Mistakes Jake Wants You to Avoid

  1. Sizing only by square footage (ignoring climate & insulation)

  2. Ignoring heating BTUs in cold states

  3. Assuming "bigger is better"

  4. Not checking the manufacturer’s low-ambient rating

  5. Forgetting to account for the ceiling height

  6. Letting sunlight trick you (sunrooms need extra BTU)

  7. Ignoring airflow obstructions (furniture, built-ins can reduce efficiency.

When you avoid these mistakes, your heat pump will perform like a champ for years.


14. Jake’s Final BTU Recommendations for Common Settings

  • Small bedroom (100–200 sq ft): 4,000–6,000 BTU

  • Large bedroom (200–350 sq ft): 6,000–8,000 BTU

  • Studio apartment (300–500 sq ft): 8,000–12,000 BTU

  • 1-bed apartment (500–700 sq ft): 12,000–15,000 BTU

  • Garage/shop (400–700 sq ft): 12,000–18,000 BTU

  • Sunrooms: Always +20% above chart

Stick to these guidelines and your heat pump will operate at its best.


15. Conclusion — Sizing Is a Formula, Not a Guess

Choosing the right BTU for your through-the-wall heat pump is more than just looking at the box or matching your neighbor’s system. It’s a precise calculation based on square footage, climate zone, insulation, ceiling height, sun exposure, and even how many people use the room. As Jake always says: “Sizing is a formula, not a guess.”

Armed with this guide, you now have everything you need to size confidently like a pro. Whether you're fitting a bedroom, apartment, garage, or office, the right BTU size ensures your heat pump works efficiently year-round with perfect comfort.

If you follow Jake’s sizing method, your through-the-wall unit will run smoother, last longer, and deliver the exact comfort you expect—no more cold winters or overheated summers, just perfect performance.

In the next blog, you will learn about Through-the-Wall Heat Pump vs Window Unit — Why It’s Not Even Close

 

The comfort circuit with jake