Key takeaway

  • 2L refrigerants are required soon — start planning.

  • R-454B delays due to supply issues — expect long waits.

  • R-454B prices are spiking — now ~$500 per cylinder.

  • R-32 is cheaper, available, and performs well.

  • Plan and handle safely to avoid costly delays.

A2L Refrigerants and the AIM Act

HVAC technicians installing A2L-compliant air conditioning system with R-32 and R-454B cylinders, safety equipment, and AIM Act compliance banner.

A2L refrigerants sit in the “mildly flammable” safety class. They release far less carbon heat (called Global Warming Potential, or GWP) than the old favorite R-410A. The American Innovation and Manufacturing (AIM) Act forces the United States to cut HFC production 85 % by 2036, so the whole HVAC market is scrambling to switch to lower-GWP blends such as R-454B and pure refrigerants like R-32. Because A2Ls are new, extra rules now cover leak detectors, ventilation, and technician training.

Unlike older A1 gases, an A2L can ignite under the exact right mix of refrigerant and air plus a spark. Codes therefore limit the charge size in small rooms and insist on automatic shut-off valves. That may sound scary, but the ignition energy is low—think about lighting a camp stove. With proper piping, sensors, and education, A2Ls are as safe as today’s natural-gas furnaces. Many manufacturers have already designed sealed cabinets, built-in leak detection, and quick-connect fittings so field work is just as familiar as R-410A systems.

Why the Industry Chose R-454B to Replace R-410A

Comparison chart of R-410A and R-454B refrigerants showing molecular makeup, pressure curve similarity, and lower global warming potential.

R-454B is a clever blend of two molecules (about 70 % R-32 and 30 % R-1234yf). Engineers picked that recipe because its pressure curve almost “copies” R-410A, letting them reuse much of the same compressors, coils, and expansion valves. That meant less redesign work and quicker time-to-market. The blend’s GWP is just 466, roughly 78 % lower than R-410A. In most lab tests R-454B matches capacity and even bumps efficiency a hair at part-load conditions.

Another big plus is licensing: major brands (Carrier, Trane, Lennox, AAON) have already certified full product lines for 2025 launch. R-454B’s mild flammability keeps field installation rules simpler than highly flammable A3 gases like propane (R-290). In short, the refrigerant seemed the perfect “drop-in with paperwork” until the unexpected cylinder crunch hit.

How the R-454B Shortage Happened

Warehouse scene with empty refrigerant shelves, a 'Filling Delay' sign at a factory, and a U.S. map showing shipping routes due to R-454B shortages

The chemical itself is plentiful. What’s missing are DOT-approved A2L cylinders and enough filling lanes at factories. Pandemic-era steel shortages, followed by new fire-testing rules, cut cylinder production almost in half. At the same time, every OEM switched its spring 2025 builds to R-454B. Those two forces smashed together, leaving empty shelves and a waiting list that can reach 90 days in summer.

For more insight, read our full breakdown:
👉 Understanding the R-454B Refrigerant Shortage in 2025

Small distributors now ration drums to “critical repairs only.” Larger national chains move stock around the country every night to chase heat-wave demand. These logistics games add freight miles and overtime, which show up on your invoice. Some techs have tried “topping off” a half-charged unit with leftover R-32 or R-410A never to do this! Mixed refrigerants separate inside the coil, killing efficiency and possibly wrecking the compressor.

Daily Impact on HVAC Contractors

HVAC technician loading limited R-454B cylinders into a van while another explains delays to a customer; checklist and Furnace Outlet portal in view.

Contractors feel the shortage first. A rooftop unit that once shipped in two weeks can now sit in a yard for months waiting for the required factory charge. Service companies must pre-order refrigerant for the whole cooling season and store it safely (remember, A2L rules call for spark-proof rooms and spill plans). Smaller shops without warehouse space lose bids because they cannot guarantee a start date. 

Facing angry building owners, technicians turn into planners and educators. Many point customers toward The Furnace Outlet parts portal so owners can track stock themselves. Good record-keeping model numbers, charge sizes, line-set lengths lets a crew grab the right number of cylinders on the first truck roll, saving precious pounds of R-454B.

HVAC expert Tony Marino also shares his take here:
👉 Tony Marino’s Take: Navigating the 2025 R-454B Refrigerant Shortage

Effects on Manufacturers and Distributors

HVAC factory halted due to refrigerant shortage, workers idle next to unfinished equipment, and distributors reviewing declining sales data and surcharges.

Original-equipment makers (OEMs) juggle two problems: component shortages (fans, chips) and now refrigerant shortages. When assembly stops, factories pay workers to do nothing or eat costly overtime later. Distributors downstream see their quarterly rebates shrink, so they raise mark-ups to keep warehouses open. Everyone in the chain fights for limited R-454B, which encourages double-ordering—artificial demand that worsens the queue. Honeywell’s surcharge (42 %) is one effort to calm that panic buying by making inventory expensive to hoard.

Project Delays and Financial Ripples

Construction site with portable chillers, 'Mission-Critical Cooling' sign, delay warnings, and an invoice showing high daily penalties for HVAC delays.

Mission-critical sites like data centers, hospitals, and pharmaceutical plants cannot run hot. When an air-handler replacement slips by six weeks, companies may spend thousands on temporary chillers or overtime for monitoring. New-build construction faces liquidated-damage clauses of $5 000-$10 000 per day. Owners then push design-build teams to find any low-GWP refrigerant the code inspector will sign off. That time pressure is why R-32 suddenly looks attractive.

That time pressure is why R-32 suddenly looks attractive.
👉 Explore R-32 Air Conditioner and Air Handler Systems

Hidden Costs: Surcharges, Tariffs and Raw Materials

Refrigerants are only part of today’s price shock. Aluminum fins, copper tubing, and electronic expansion valves all jumped nearly 30 % since 2020. Add freight fuel, the Honeywell surcharge, plus the 301-tariff on Chinese HVAC goods, and a mid-size RTU costs roughly 10 % more than last year. Budget estimates from 2023 are now useless, so engineers should apply a fresh multiplier before locking bids.

Read more on ENERGY STAR HVAC Cost Efficiency

R-32 vs R-454B: Performance Head-to-Head

Side-by-side comparison of R-32 and R-454B refrigerants showing cost, GWP values, cooling capacity, and performance metrics.

R-32 is a single molecule, so it never fractionates; technicians can top up or reclaim with no glide worries. It runs slightly higher discharge temperature than R-454B, but scroll compressors handle that with optimized oil and vapor-injection. Lab data show 3-7 % more cooling capacity for R-32, which means a smaller coil can deliver the same BTUs. Because supply is healthy, cylinders cost half as much. The trade-off is GWP: 675 for R-32 versus 466 for R-454B. Both beat R-410A’s whopping 2088 figure.

Learn more from AHRI on Refrigerant Safety and Classification

Safety and Environmental Comparison

Flammability numbers look scary until you dig deeper. The Lower Flammability Limit (LFL) of R-32 is 14 % by volume; R-454B’s is 8.1 %. That means R-454B actually ignites more easily if a big leak happens indoors. Both gases are classed A2L (low toxicity), so ventilation and leak detection rules are identical. From a climate view, R-454B wins with its lower GWP, yet life-cycle analyses show total carbon footprint depends more on energy efficiency than refrigerant choice. Maintaining clean filters and tight ducts saves more CO₂ than the extra 200 GWP points.

Converting Existing Equipment to R-32

Step-by-step HVAC system retrofit illustration showing oil change, sensor upgrade, expansion valve verification, and equipment relabeling for R-32 use.

Can you re-use a unit designed for R-454B but charged with R-32? Often, yes—if you:

  1. Evacuate all refrigerants and change oil to POE grade that matches the compressor seal kit.

  2. Verify expansion device sizing (R-32 needs 5-10 % larger orifice).

  3. Upgrade leak sensors to R-32 calibration.

  4. Update labels and owner manuals so future techs know what is inside.

These steps fit in a normal eight-hour shift for a 5-ton split system. Larger chillers may need factory firmware to tweak superheat tables. Despite the work, owners still save money thanks to cheaper gas and future availability.

Planning Tips for Facility Managers in 2025

Facility manager reviewing a planning checklist with hybrid HVAC system in background using R-32 VRF for cooling and boilers for winter heat.
  • Forecast what you’ll need. List every system over 10 lb of charge and its refrigerant type.

  • Order early. Place R-454B cylinder orders 60-90 days in advance.

  • Stock spare parts, especially contactors and sensors unique to A2L units.

  • Train staff on new safety checks: gas monitors, evacuation times, and spark-free tools.

  • Consider hybrids. Pair an R-32 VRF system for cooling with existing boilers for winter heat to slash annual GWP without touching every coil.

Following these steps keeps critical cooling online and protects the maintenance budget from surprise surcharges. 

Long-Term Refrigerant Strategy

Future roadmap showing HVAC refrigerant paths including R-32, HFO-1234ze, and CO2 systems, with technician using tablet for digital charge tracking.

No single refrigerant will rule forever. The AIM Act’s technology-transitions program already signals tighter GWP caps by 2035. That pushes R-32 near the limit and may favor even lower options like hydrofluoro-olefins (HFO-1234ze) or natural CO₂ systems. Still, the skills you build today—safe A2L handling, smart leak detection, digital charge-tracking—apply to any future gas. Hedge your bets: design machines with wide operating envelopes, choose controls that can upload new refrigerant tables, and keep strong supplier ties so you are first in line when the next transition begins.


Frequently Asked Questions

Q: What is an A2L refrigerant?
A: A gas that is mildly flammable (Class 2L) and has low toxicity (Class A) under ASHRAE Standard 34.

Q: Why can’t I just keep using R-410A?
A: Federal law will restrict high-GWP HFCs; OEMs will stop making compatible equipment and parts.

Q: Is R-32 safe in my house?
A: Yes, when installed to code with leak detection and proper airflow. Millions of units already run on R-32 worldwide.

Q: Can I mix R-454B and R-32 to “stretch” supply?
A: No. Mixing refrigerants creates unsafe pressures, ruins efficiency, and voids warranties.

Q: Will prices drop after 2025?
A: Probably. As more cylinder factories earn A2L approvals and distribution stabilizes, surcharges should shrink.