Cooling rules of thumb what works, where it breaks

The classic shortcut is 1 ton per 400–600 ft² of conditioned space. In efficient homes (tight envelope, good glazing, solid shading), you may see 1,000–1,400+ ft² per ton; poorly insulated or leaky spaces trend the other way. Converted to sensible capacity, a practical pre-calc is ~20–25 BTU/ft² for standard builds; 100–120 BTU/ft² isn’t unusual for poorly insulated bonus rooms or sunrooms. Use these only to frame options before Manual J.
Visual:

Rule of Thumb Ladder (Cooling)

Leaky/Attic Room  ─────────── 100–120 BTU/ft²

Typical 1990s Home ────────── 20–25 BTU/ft²

High-Perf / New Build ─────── 10–15 BTU/ft² (often 1,000+ ft²/ton)

If the “thumb” suggests upsizing but the home is tight with low SHGC windows, pause and verify with load data. For product exploration by capacity, browse R-32 AC & air handler systems.

Heating by climate zone start with BTU/ft², then verify

Heating demand rides mostly on design temperature and envelope. As a pre-calc, use:

  • Zone 1 (Hot): 30–35 BTU/ft²

  • Zone 2 (Warm): 35–40 BTU/ft²

  • Zone 3 (Moderate): 40–45 BTU/ft²

  • Zone 4: 45–50 BTU/ft²

  • Zone 5 (Cold): 50–55 BTU/ft²

These get you in the ballpark for picking tiers to quote. Expect lower BTU/ft² in high-performance shells and higher in drafty, uninsulated spaces. Pair rules with local design temps for a sanity check; then run Manual J to lock it in. If you’re considering dual-fuel or all-electric strategies, map loads to equipment curves early. See R-32 AC & gas furnaces for cold-climate options.

“How many tons for my square footage?”

A 2,000 ft² home can reasonably need ~2–5 tons depending on climate, insulation, glazing, airtightness, and internal gains. That wide range is why simple ft²/ton is risky. Quick estimator:

Cooling BTU ≈ (ft² × 20–25)

             + 400 × (occupants – 1)

             + 4,000 (kitchen)

             + 1,000 × windows

             + 1,000 × exterior doors

Adjust: –10% heavy shade / +10% high sun exposure

Use the result to shortlist models and discuss tradeoffs (SEER2/HSPF2, dehumidification, turndown). Then schedule a load calc. For right-sized equipment by tonnage, see for room-by-room projects or package units for rooftops and tight footprints.

Replacements stop matching the old nameplate

“Same size as before” is often wrong. Legacy installs frequently used 400–600 ft²/ton without accounting for envelope upgrades, window replacements, or duct corrections made since. The result is chronic oversizing: short cycling, humidity problems, hot/cold rooms, and unnecessary utility spend. Before approving a like-for-like, re-measure conditioned area, count occupants, windows, and doors, note solar exposure, and check attic/wall R-values. If loads dropped, step down capacity or move to equipment with better turndown (two-stage or inverter). Explore high-efficiency air handlers.

“BTUs per square foot” use a range, not a single number

BTU/ft² is a heuristic, not a spec. Cooling 20–25 BTU/ft² fits many standard shells; poorly insulated rooms can require 100–120 BTU/ft². Heating spans ~30–55 BTU/ft² with climate. What swings the number? Envelope U-values, infiltration, glass area/orientation, ceiling height, and internal gains. Normalize loads by volume for tall spaces (two-story foyers, vaulted ceilings) to avoid underestimating sensible load. Rapid screen: if a rule-based pick implies <30% duty cycle at design or can’t hold RH <55% in summer, it’s probably oversized on sensible and undersized on latent control. For humidity-sensitive homes, favor multi-stage/inverter systems with low CFM per ton capability. Browse options across staging levels in R-32 packaged systems.

Envelope, glass, height, and tightness why ft² isn’t enough

Square footage ignores the big drivers: insulation continuity, window/door U-factors and SHGC, orientation, and infiltration. Tall volumes add air to condition and stratification to fight. Checklist visual:

[ ] Attic R-value ____   [ ] Wall R-value ____

[ ] ACH50 (tightness)   [ ] Ducts sealed/insulated?

[ ] Window U/SHGC       [ ] Orientation (E/W glass?)

[ ] Roof color/material [ ] Shading/overhangs

Airtight homes with right-sized equipment run longer, steadier cycles that control humidity better. Pro move: If infiltration is unknown, add a conservative buffer to sensible and latent loads, then revisit after a blower-door or use local ACH proxies. Considering room-by-room improvements? A zoned approach with ductless wall-mounted heads can solve orientation and glass asymmetries cleanly.

Occupants, kitchens, and plug loads internal gains that matter

People and appliances add real heat. As a fast input, add ~400 BTU per extra occupant, ~4,000 BTU for active kitchen areas, and ~1,000 BTU per large sun-exposed window or exterior door when estimating. Always reconcile these with lifestyle: work-from-home offices, exercise rooms, and media spaces run hotter. Field tip: Where kitchens and great rooms share volume, prioritize latent control—select equipment that can drop CFM at low load and maintain coil temps for dehumidification. This is where inverter mini-splits shine; see DIY ductless and concealed-duct systems for clean aesthetics.

Oversized vs. undersized failure modes you can spot

Oversized gear short-cycles, misses latent removal, creates temperature swings, and wears components with constant starts. Expect clammy rooms and uneven temps, especially in shoulder seasons. Undersized systems run continuously, struggle at peaks, and elevate energy use due to long compressor hours; some rooms never stabilize. Both cases push callbacks. Diagnostic visual:

Short cycles + high RH → likely oversized

Long continuous run + can’t hit setpoint → likely undersized

Meets setpoint but RH > 55% → check CFM/ton & latent capacity

Sizing isn’t just comfort it’s compressor life and bill predictability. If you inherit a problem home, right-size and verify airflow (350–400 CFM/ton target unless dehumidification strategy dictates lower). For spaces that need dedicated conditioning, consider through-the-wall units.

Manual J done right what gets counted (and why it changes sizing)

A professional Manual J factors precise dimensions and orientation, insulation assemblies, window and door specs, local design temps, duct efficiency, and internal gains room by room. Studies routinely show Manual J yielding far higher ft²/ton (≈1,431 on average) than old rules, which means many homes have been 2–3× oversized historically. 

Pair Manual J with Manual S (equipment selection) to match sensible/latent split and with Manual D to ensure ducts deliver the calculated CFM. That’s how you get quiet, even, and dry comfort. Ready to formalize? Start at the Design Center or review the Sizing Guide.

Regional patterns design temps, dehumidification, and ft²/ton

Climate steers priorities: hot/humid regions favor cooling + latent control; cold regions need heating capacity and freeze protection; mixed climates need flexible staging and smart controls. Typical observed ranges: Zones 1–2: ~600–1,100 ft²/ton, Zone 3: ~600–1,200, Zone 4: ~700–1,350, Zone 5: ~700–1,400 for common 1.5–5-ton systems. Treat these as context, not prescriptions. In Gulf or coastal markets, target equipment that can run long and dry at low CFM; in northern markets, confirm low-ambient performance and supply-air temps that feel comfortable at part load. Explore R-32 residential packaged heat pumps where utility rates or design temps justify them.