Installation Guide What Tony Learned Setting Up His 2-Ton Goodman System

A Real-World Walkthrough for Homeowners Who Want to Do It Right

Hey folks — Tony here again.

I’ve installed more air conditioners than I can count, but there’s nothing like doing one in your own house. When my old 1.5-ton system finally threw in the towel last summer, I decided it was time for a real upgrade — something reliable, efficient, and built to last.

After comparing models, I landed on the Goodman 2-Ton 14.3 SEER2 Single-Stage Air Conditioner Condenser (Model GSXN402410) — the perfect match for my 1,200-square-foot home.

This guide isn’t a dry technical manual. It’s the real story of what I learned setting up my Goodman system — every lesson, shortcut, and “wish I’d known that sooner” moment that can save you time, money, and frustration.

Let’s dive in.


🧊 Step 1: Planning and Preparation — “Half the Battle Happens Before You Start”

Before lifting a wrench, I sat down with my notepad and calculator.

🔹 Load Calculation

First up: figuring out my cooling load.
I ran a Manual J-style calculation using an online BTU estimator to confirm that a 2-ton system (24,000 BTU/h) was the right size. My home has good insulation, newer windows, and moderate climate exposure — so 2 tons was spot on.

🔹 Matching Equipment

I paired the GSXN402410 condenser with a Goodman CAPFA2318B6 coil — a proven combination that keeps the SEER2 rating intact and warranty valid.

🔹 Tools Checklist

I made sure every tool was ready:

  • Vacuum pump and micron gauge

  • Torque wrench

  • Nitrogen tank and regulator

  • Refrigerant gauge manifold

  • Electrical multimeter

  • Flaring and brazing tools

  • Level and concrete pad

🔹 Site Prep

I cleaned out the condenser area beside my house, leveled the ground, and poured a new 3-inch-thick concrete pad with vibration-damping feet.

Then, I shut off power at the disconnect and flipped the breaker at the main panel. Safety first — always.

“If you don’t plan your job, the job will plan you. Preparation isn’t optional; it’s everything.”

📘 Reference: Energy.gov – Central AC Installation Tips


⚙️ Step 2: Removing the Old System

Removing an old unit is part demolition, part archaeology.

🧯 Recovering Refrigerant

EPA regulations make it clear: you must recover refrigerant properly. I hooked up my recovery machine and pulled the R-22 from my old condenser into a certified recovery tank.

📘 Reference: EPA – Section 608 Refrigerant Handling

🔌 Disconnecting and Cleanup

I shut down the disconnect, pulled the whip, and carefully unsweated the old copper line set. The old suction line showed some black oxidation — a clear sign it needed replacing.

Within 45 minutes, the 15-year-old condenser was off its pad and on the dolly.

“Don’t cut corners here. A contaminated line set or leftover refrigerant can kill a brand-new compressor before the warranty ink dries.”


🧩 Step 3: Installing the New Goodman GSXN402410 Condenser

Goodman makes this part straightforward.

🔹 Setting the Unit

I placed the GSXN402410 on the new pad, ensuring 24 inches of clearance around it for airflow. I used rubber isolators under the feet to minimize vibration.

🔹 Connecting the Line Set

A new 25-ft line set (3/4" suction, 3/8" liquid) went in. I kept my bends gradual to maintain refrigerant velocity. Using nitrogen flow while brazing prevents scale inside the pipes.

🔹 Wiring

High-voltage power connected to L1 and L2 in the contactor. The control wires (yellow to Y, brown to C) tied neatly into the low-voltage block.

Goodman’s labeling is crystal clear — one reason I love their units.

🔹 Electrical Check

I confirmed the disconnect box was within 6 ft of the unit and that the breaker was properly rated (30 amp, 240 V).

“I’ve worked on plenty of systems where sloppy wiring turned a one-hour startup into a full-day headache. Take five minutes to tighten every lug.”

📘 Reference: Goodman GSXN4 Installation Manual


🌡️ Step 4: Installing the Indoor Coil and Air Handler

Inside, I replaced my old coil with a Goodman CAPFA2318B6.

🔹 Coil Placement

The airflow arrow on the coil always points toward the blower. I slid it into the plenum, sealed it with foil tape and mastic, and made sure condensate drains were properly trapped.

🔹 Brazing & Pressure Test

Using nitrogen, I brazed the copper lines into the coil fittings. Then I pressurized the system to 150 psi with nitrogen and soap-tested every joint.

No bubbles, no leaks. Perfect.

🔹 Condensate Line

I glued and trapped a new ¾-inch PVC drain, pitched slightly downward for gravity flow.

“Skip nitrogen while brazing, and you’ll create soot inside the lines. That carbon finds its way into your TXV and ruins efficiency down the road.”

📘 Reference: ACCA – Manual S Equipment Selection


⚡ Step 5: Evacuation and Charging

Now for the science part.

🔹 Pulling Vacuum

I connected my micron gauge and pulled the system down to 500 microns. I let it sit for 15 minutes — it held steady at 490. That means no leaks and no moisture.

🔹 Releasing Refrigerant

The GSXN402410 ships pre-charged with R-410A for a 15-ft line set. My run was 25 ft, so I added 3 ounces of refrigerant per Goodman’s spec.

🔹 Superheat & Subcooling

After startup, my gauges read:

  • Suction: 118 psi

  • Head: 370 psi

  • Subcooling: 11 °F

  • Superheat: 9 °F

Exactly within Goodman’s range.

“When you hit target pressures on the first try, it’s not luck — it’s prep and patience.”

📘 Reference: ACCA – Quality Installation Standards


🧾 Step 6: Startup and Testing

The moment of truth.

I flipped the disconnect, powered on the thermostat, and waited. The compressor kicked in with a low hum, the fan spun, and cool air filled the vents in under a minute.

I measured:

  • Supply temperature: 55 °F

  • Return temperature: 75 °F

  • ΔT: 20 °F (right on target)

I checked for vibration and verified the contactor wasn’t buzzing. Quiet, steady, and cold — exactly what I wanted.

“I still stand beside every system I install for the first 20 minutes. You can’t fake performance numbers; they’ll tell you if the install’s right.”


🔧 Step 7: Post-Installation Maintenance Checklist

A good install doesn’t end when it cools.

Tony’s Checklist:

  1. Seal wall penetrations around the line set with foam.

  2. Label all circuit breakers and disconnects.

  3. Register warranty at Goodman’s website within 60 days.

  4. Replace filter after 30 days.

  5. Add system specs (model, serial, charge) to a service tag on the unit.

📘 Reference: Goodman – Warranty Registration Portal


🧠 Step 8: Lessons I Learned

Even after years in HVAC, this install reminded me of some timeless truths.

✅ Preparation Beats Panic

Gather everything before day one. Missing one 90-degree elbow can stall the whole project.

✅ The Vacuum Test Is Non-Negotiable

If you skip it, you’ll pay for it later with compressor burnout.

✅ Good Airflow Matters More Than Anything

A new system with clogged filters or bad ducts performs like an old one.

✅ Documentation Protects Your Warranty

Photos, serial numbers, pressure readings — they prove the install was done right.

“Goodman’s hardware is solid. The only weak link in any system is the installer who gets in a hurry.”


🧾 Step 9: Why Goodman’s Design Made the Job Easier

Every manufacturer builds systems differently. Goodman stands out because it’s designed for practicality.

🔹 Pre-Charged for Standard Line Length

No juggling refrigerant weights for common installs.

🔹 Compact Cabinet

At 26" square, it fit easily in my side yard.

🔹 Scroll Compressor

Runs quieter and smoother than older reciprocating units.

🔹 Clear Wiring Labels

No guesswork — every contactor, capacitor, and relay is marked.

🔹 Serviceability

Single access panel = faster troubleshooting later.

“I’ve installed premium brands that felt over-engineered. Goodman keeps it simple — and that’s what makes it reliable.”


💡 Performance Results After 30 Days

After a month of operation, here’s what I noticed:

  • My home cools faster — average cycle 10–12 minutes instead of 20.

  • Power bill dropped ≈ 18 %.

  • Noise level outside fell to about 70 dB (same as a dishwasher).

  • System pressures stayed steady even on 95 °F days.

The 2-ton Goodman performs exactly as advertised — efficient, consistent, and quiet.


🧩 Final Takeaway from Tony

Installing my Goodman 2-Ton system wasn’t just another job — it was proof that simple, well-engineered systems still win the day.

When you follow the fundamentals — proper prep, vacuum integrity, precise charging, and clean airflow — you don’t need a fancy brand to get premium results.

So, if you’re upgrading your cooling this year, here’s my honest advice:

“Get a good plan, take your time, and don’t skip the details. A Goodman done right will run quietly for 15 years — and you’ll never think about it again, except when you’re grateful for the cold air.”

Stay cool,
— Tony