(By Tony the Trusted Tech)

Here’s the truth:
The #1 reason most HVAC systems underperform isn’t the brand. It’s the sizing.

Oversized or undersized, it doesn’t matter — if your unit’s not matched to the actual load of the space, you’re in for higher bills, uneven temps, and equipment that wears out before its time.

I’ve seen it too many times. A homeowner spends thousands on a high-efficiency system, but the installer eyeballs the square footage and slaps in a 4-ton unit where a 3-ton would’ve crushed it.

Let’s break down why HVAC sizing matters, how it really works, and the biggest mistakes you can avoid if you want your system to last and perform like it should.


Why Proper HVAC Sizing Is Critical

Think of your AC like a truck. Bigger engines aren’t always better — they just burn more fuel if they’re not towing a heavy load.

Same deal with HVAC.

Oversized systems short cycle (turn on and off too fast), which:

  • Spikes your energy bills

  • Fails to remove humidity

  • Wears out compressors prematurely

Undersized systems run constantly, which:

  • Still doesn’t hit the temp you want

  • Runs up the electric bill

  • Overloads the blower and coil

Either way, your system’s wasting money and fighting a losing battle.

Want to see the science? The U.S. Department of Energy’s HVAC sizing guidelines explain how poor sizing leads to both energy loss and poor dehumidification.


The Most Common HVAC Sizing Mistakes

Here’s what I’ve seen in the field, time and time again.

1. Using Only Square Footage

This is HVAC sin #1.
You can’t just go “500 square feet = 1 ton” and call it a day.

Why?
Because load is affected by:

  • Insulation

  • Window types and direction

  • Ceiling height

  • Duct layout

  • Occupants and appliances

For example, a 1,500 sq. ft. house in Arizona with west-facing glass walls is a whole different beast than one in Michigan with shade trees and spray foam insulation.

Correct Method:
Use Manual J load calculation — the industry standard for residential HVAC sizing.

More on that here from ACCA (Air Conditioning Contractors of America).


2. Ignoring Ductwork and Static Pressure

Let me guess — your ductwork’s from the 1990s and hasn’t been touched since.

Even if your new system is perfectly sized, if it’s pushing air through undersized, leaky, or unbalanced ductwork, you’re throwing SEER2 efficiency out the window.

Real talk:
Most homes have way more duct restriction than their blower motors are rated for. SEER2 testing uses 0.5" static pressure — your house might be hitting 0.8".

Use a static pressure test or ask your tech for a full Manual D analysis. More info from the Energy Vanguard blog on duct design.


3. Forgetting About Climate Zones

What works in Georgia doesn’t work in Maine.

Hot, humid climates = bigger latent load (you need dehumidification).
Cold climates = bigger heating demand (you need a furnace that won’t cycle).

HVAC sizing needs to factor in:

  • Heating Degree Days (HDD)

  • Cooling Degree Days (CDD)

  • Humidity levels

  • Seasonal temperature swings

Your local utility likely has load calculators or weather data. 


What Happens When the Unit’s Too Big?

Oversized HVAC isn’t just wasteful. It’s bad for comfort.

Symptoms of Oversizing:

  • Cold and clammy rooms (bad humidity control)

  • Frequent cycling (compressor wear)

  • Higher repair costs over time

  • Bad airflow due to short blower runtimes

If you’ve had a system replaced and now it cools too fast but still feels damp or sticky, you’ve probably been oversized.

It’s like putting a V8 in a go-kart. You’re not getting more control — just more problems.


How to Size It Right: What I Recommend

If you're serious about sizing it right, do this:

1. Request a Manual J Calculation

It’s not optional anymore. It’s required in many jurisdictions for permits, and it’s the only way to legally size a system to code.

It factors in:

  • Floorplan layout

  • Insulation R-values

  • Window and door specs

  • Solar orientation

  • Internal loads (appliances, people)

Your contractor should use software like Wrightsoft or CoolCalc — not guesswork.

2. Check the Ducts (Manual D)

You need ductwork that supports the air volume and static pressure of the unit.

Most of the time, I end up reworking or upsizing return air on installs — especially on high-efficiency or variable-speed systems.

3. Match Your Unit to the Load

This is where the Goodman 3 Ton 14.5 SEER2 R-32 system shines.

It’s a sweet spot for:

  • 1,600–1,800 sq. ft. homes (with moderate load)

  • High-efficiency R-32 refrigerant = faster heat exchange

  • Works well with upgraded duct systems

If you’re unsure, check out Energy Star’s HVAC buying guide for more info on matching system size to load.


Final Word: Don’t Size on Guesswork

Look, sizing your HVAC system isn’t flashy — but it’s the single most important factor in performance, longevity, and efficiency.

The Goodman 3 Ton 14.5 SEER2 R-32 system is a killer unit — but if you put it in the wrong environment, or match it to bad ductwork, you’re wasting its potential.

Spend the extra time (or a few hundred bucks) on a real load calc. It’ll save you thousands over the life of your system.

Buyer's guidesTony’s toolbox talk

Leave a comment

All comments are moderated before being published