Troubleshooting R-32 Furnace/AC Combos: 10 Common Issues and How to Fix Them

⚡️ Introduction: Real-World HVAC Repairs Start Here

Hey, it’s Tony again—coming to you from the land of crawlspaces and rooftop units. Today we’re tackling a topic I see in the field all the time: troubleshooting R-32 combo systems.

Whether you’re a homeowner hearing weird noises from your vents or a tech staring down a pressure gauge that just doesn’t make sense, this guide has you covered. We’re talking through 10 of the most common issues I’ve run into when servicing 3-ton R-32 AC and gas furnace combos like the ones over at The Furnace Outlet.

Let’s dig into the problems—and the fixes. 🔧

 

1. 🌀 System Short Cycling

Symptoms: Unit turns on and off frequently without cooling or heating effectively.

Fixes:

  • Check thermostat location—if it’s too close to a vent, it’ll shut off prematurely.

  • Inspect for dirty air filters or clogged return vents.

  • Verify that the charge weight matches factory specs—too much or too little R-32 can cause erratic cycling.

👉 More on this from Energy Star’s maintenance guide.

 

2. 🔥 Furnace Won’t Ignite

Symptoms: Blower comes on but no heat, or a rapid-clicking ignition sequence.

Fixes:

  • Clean flame sensor with emery cloth.

  • Confirm proper gas pressure with a manometer.

  • Ensure the furnace exhaust is not blocked (common with snow or leaves).

Check with the International Code Council for local requirements around combustion air and venting.

 

3. ❄️ Weak Cooling Performance

Symptoms: System runs, but indoor temps stay high.

Fixes:

  • Confirm outdoor coil is clean and not restricted.

  • Check refrigerant charge using superheat and subcooling values.

  • Use a combustible gas detector to ensure no slow R-32 leak is present.

The AHRI R-32 Toolkit offers helpful charge calculators and pressure charts.

 

4. 🚫 Tripped Breaker or Blown Fuse

Symptoms: Complete loss of power to furnace or condenser.

Fixes:

  • Inspect capacitor and contactor on condenser.

  • Check for grounded wires or short circuits.

  • Test blower motor amperage draw.

R-32 units often come with ECM blower motors that pull more current at startup.

 

5. 🧊 Frozen Evaporator Coil

Symptoms: Visible frost on coil or suction line, reduced airflow.

Fixes:

  • Turn off system and let ice melt.

  • Replace dirty filters and confirm blower speed settings.

  • Inspect TXV valve for restriction.

You can cross-check the ideal operating range from The AC Outlet's technical documentation.

 

6. 💨 Loud or Unusual Noises

Symptoms: Rattling, buzzing, or humming from indoor or outdoor unit.

Fixes:

  • Tighten loose cabinet screws and check for refrigerant line vibration.

  • Inspect blower wheel for balance.

  • Lubricate motor bearings if applicable.

 

7. ⚠️ High-Pressure Lockout

Symptoms: AC shuts down, diagnostic lights indicate high pressure.

Fixes:

  • Clean condenser coil thoroughly.

  • Confirm proper airflow around the unit (12" minimum clearance).

  • Double-check line set for kinks or collapsed insulation.

For more pressure and temperature thresholds, consult EPA’s MVAC refrigerant resources.

 

8. 🚿 Water Leaks or Drainage Issues

Symptoms: Water pooling near air handler or furnace.

Fixes:

  • Flush condensate drain line with vinegar.

  • Check for float switch activation.

  • Inspect secondary drain pan and PVC connections.

 

9. 🔄 Blower Runs Nonstop

Symptoms: Blower continues after cooling/heating ends.

Fixes:

  • Check if the fan mode is set to “On” instead of “Auto.”

  • Test the fan relay on the control board.

  • Inspect for a faulty limit switch.

 

10. 📉 Low Gas Furnace Efficiency

Symptoms: System heats, but bills are too high or comfort is inconsistent.

Fixes:

  • Adjust gas manifold pressure to manufacturer specs.

  • Ensure return and supply ducts are properly sealed.

  • Perform combustion analysis and adjust air-fuel mix.

 

🧠 Final Thoughts: Know the Signs, Solve the Problem

Troubleshooting R-32 systems isn’t about guesswork—it’s about knowing the signs and using the right tools. When in doubt, always refer to manufacturer documentation, and remember: A2L refrigerants like R-32 require extra care during service.

Want to know if your home is ready for R-32? Click this link about Clearance, Ventilation & Code Checks.

Need tools, systems, or expert-approved HVAC packages? Head over to The Furnace Outlet’s R-32 collection.

Stay safe and stay sharp.
—Tony 🔍🧰