Cooling Issues Solved: Common Problems on the Goodman GLXS4BA6010 & AMST60DU1300

Jake's Hello

Yo, it’s Jake. So your Goodman 5-Ton 14 SEER2 R-32 system isn’t keeping your home ice-cold? Don’t panic. I’ve seen it all: weird noises, poor airflow, coils freezing, and even mysterious water leaks. Today, we’re going full Jake mode to break down the most common issues with the GLXS4BA6010 condenser and AMST60DU1300 air handler—and show you exactly what you can do to fix ’em.

I’ll give you practical advice, explain what’s safe to DIY, and when it’s time to call in a licensed pro. By the end, your system will be back to humming smoothly, and you’ll understand exactly what went wrong in the first place. Let’s dive in! 🚀

 

1. Poor Cooling or Weak Airflow

One of the most common complaints is the house just isn’t getting cold enough, or airflow feels weak. Here’s what to check:

1.1. Check Your Air Filter

A clogged filter is like putting a pillow over your blower—it chokes airflow and efficiency. Replace every 1–3 months depending on usage. For tips on choosing the right filter, check out this resource: EPA Guide to Air Filters.

1.2. Inspect Ductwork

Leaks, disconnected sections, or crushed ducts can cut airflow dramatically. Look for obvious holes, loose joints, or disconnected flex duct. Properly sealed ducts save energy and improve comfort.

1.3. Check Blower Settings

The AMST60DU1300 air handler has multiple blower speeds. Make sure the thermostat fan setting is correct and blower is running at full speed when cooling.

 

2. System Not Cooling at All

If the condenser is running but your home isn’t cooling, the issue might be more serious:

2.1. Thermostat Issues

Make sure your thermostat is set to cool, the temperature is below room temp, and batteries are fresh.

2.2. Electrical Problems

Check breakers and fuses. A tripped breaker or blown fuse can stop the compressor or blower. For a reliable electrical troubleshooting guide, see: Goodman AC Electrical Safety Tips.

2.3. Refrigerant Issues

Low refrigerant can prevent cooling. R-32 charging should only be handled by a certified professional. Leaks need to be detected and repaired before refilling.

 

3. Frozen Evaporator Coil

A frozen coil is a classic sign of airflow or refrigerant problems:

  • Dirty filters reduce airflow and can freeze coils.

  • Blocked vents or ducts limit air movement.

  • Low refrigerant charge causes the coil to drop below freezing.

Tip: Turn off the system and let the coil thaw before troubleshooting. A DIY freeze-thaw guide from Energy Star is helpful: Energy Star HVAC Maintenance.

 

4. Strange Noises

Weird sounds coming from your condenser or air handler often indicate underlying issues:

  • Rattling – loose panels or debris in the condenser.

  • Squealing – blower motor issues.

  • Banging – compressor startup problems or duct expansion.

Quick fixes include tightening panels, checking mounts, or lubricating the blower motor shaft if applicable. For a full guide on common AC noises, see: HVAC.com Noise Troubleshooting.

 

5. Water Leaks

Leaking water inside your home is usually from the air handler’s condensate drain line.

  • Make sure the drain is clear. A small wet/dry vacuum can help remove blockages.

  • Check the pan for cracks or misalignment.

  • Inspect float switches and pumps if present.

Proper maintenance prevents water damage and keeps your system efficient.

 

6. Error Codes and Safety Switches

The GLXS4BA6010 and AMST60DU1300 sometimes flash codes on the control board:

  • Compressor lockout – often due to electrical or pressure issues.

  • Fan errors – typically a motor or sensor problem.

Always note the code before troubleshooting, and consult the Goodman manual for code definitions.

 

7. Preventive Maintenance Tips

  • Replace filters regularly.

  • Keep condenser coils clean.

  • Seal duct leaks and check airflow.

  • Schedule professional inspection yearly.

Preventive care avoids common cooling issues and extends system lifespan.

 

8. When to Call a Pro

If troubleshooting doesn’t resolve:

  • Persistent low refrigerant

  • Electrical faults you can’t safely fix

  • Frozen coils that recur immediately

  • Strange compressor sounds

It’s time to call a licensed HVAC technician. Safety first, always.

 

Jake's Final Thoughts

Alright, you’ve officially leveled up in understanding the Goodman 5-Ton 14 SEER2 R-32 system. From weak airflow to frozen coils and error codes, you now know exactly what to check, what’s safe to fix yourself, and when to call in a pro.

Remember: a little preventative maintenance goes a long way. Keep filters fresh, ducts sealed, and coils clean, and your GLXS4BA6010 condenser and AMST60DU1300 air handler will reward you with years of cool, comfortable air.

And hey, if you want to revisit the full system specs, manuals, or plan upgrades, check out the official bundle here: Goodman 5-Ton 14 SEER2 R-32 System.

Need electrical setup tips for this bundle? Visit my guide: From Breakers to Blowers.

Stay chill, stay safe, and keep showing your system who’s boss! 😎

- Jake, your comfort loving tech!