Troubleshooting Your Goodman MBVK Electric Furnace: When the Fan Runs But No Heat

Few things are more frustrating for homeowners than turning on the heat and discovering that your furnace fan runs, but no heat is coming through your vents. Whether it’s a furnace fan running but no heat, furnace blower working but no heat, or your furnace fan turns on but no heat, understanding why this happens can save you time, money, and stress.

In this guide, I’ll explain the common causes behind a furnace that won’t heat despite the fan running, walk you through troubleshooting steps, and show you how the Goodman MBVK electric furnace is designed to handle these issues with modern technology.


Understanding the Problem: Furnace Fan Runs But No Heat

When your furnace fan works but no heat is coming out, it’s a symptom of an issue in the heating cycle. The fan and blower motor may operate normally because they are part of the airflow system, which is controlled separately from the heating elements.

Key symptoms include:

  • Furnace fan on but no heat – Air blows, but it remains cold.

  • Furnace blower working but no heat – The blower motor runs, but the heating elements don’t energize.

  • Furnace fan turns on but no heat – Sometimes the thermostat is satisfied, but other times it signals a system issue.

These symptoms are common across electric furnaces, including older units and modern systems like the Goodman MBVK. The difference is that the MBVK includes diagnostic LEDs and control board logic that help pinpoint the issue faster.


Common Causes of Furnace Fan Running But No Heat

There are several potential reasons why your furnace fan is operating, but your home isn’t warming up:

1. Thermostat Issues

The thermostat signals the furnace to heat. If it’s set incorrectly, malfunctioning, or wired improperly, it may fail to call for heat even when the fan turns on.

Troubleshooting tip:

  • Ensure the thermostat is set to “Heat” and the temperature is above room temperature.

  • Replace batteries if applicable.

  • Verify wiring connections to the furnace.


2. Tripped Circuit Breaker or Blown Fuses

Electric furnaces rely on high-voltage circuits to power heating elements. If a breaker trips or fuse blows, the blower may still run, but the elements won’t energize.

Troubleshooting tip:

  • Check your home’s electrical panel for tripped breakers.

  • Reset the breaker or replace blown fuses.

  • Inspect the furnace disconnect switch.

For more details on electric furnace safety and breaker checks, refer to the Department of Energy’s guide to electric heating systems.


3. Faulty Heating Elements

In electric furnaces, the heating elements are responsible for producing warm air. If one or more elements fail, you may experience situations where the furnace fan runs but no heat.

Troubleshooting tip:

  • Turn off the power to the furnace before inspecting.

  • Visually inspect the elements for breaks, burn marks, or corrosion.

  • Test continuity using a multimeter.

  • Replace any damaged elements with compatible Goodman MBVK parts.


4. High-Limit Switch or Safety Sensor Tripped

The high-limit switch is a safety device that shuts down the heating elements if the furnace overheats. If the switch trips, the blower may continue running while the heating stops.

Troubleshooting tip:

  • Reset the furnace if equipped with a manual reset button.

  • Ensure airflow isn’t blocked by dirty filters or closed vents.

  • Inspect the high-limit switch for damage and replace if necessary.


5. Control Board or Relay Issues

The furnace control board manages signals between the thermostat, blower, and heating elements. A faulty control board or relay can result in a scenario where the furnace fan works but no heat.

Troubleshooting tip:

  • Check for diagnostic LEDs or error codes on the Goodman MBVK control board.

  • Inspect for loose wires or burned components.

  • If the board is damaged, consult a licensed technician for replacement.


6. Airflow Problems

Improper airflow can cause the furnace to overheat or prevent heating elements from energizing. Blocked ducts, closed vents, or dirty filters can trigger safety mechanisms that stop heat production while the fan continues to run.

Troubleshooting tip:

  • Replace or clean air filters.

  • Ensure vents are open and unobstructed.

  • Inspect ductwork for leaks or blockages.


Step-by-Step Troubleshooting: Fan Runs But No Heat

If your furnace fan turns on but no heat, here’s a structured approach:

Step 1: Check Thermostat and Settings

  • Confirm the thermostat is set to “Heat” and at a higher temperature than room temp.

  • Replace batteries and verify correct wiring.

Step 2: Verify Electrical Power

  • Check circuit breakers and fuses.

  • Ensure the furnace disconnect switch is on.

Step 3: Inspect Heating Elements

  • Turn off power to the furnace.

  • Visually inspect elements and test for continuity.

  • Replace damaged elements.

Step 4: Examine Safety Devices

  • Inspect high-limit switches and reset if needed.

  • Check for tripped or malfunctioning sensors.

Step 5: Evaluate the Control Board

  • Look for diagnostic LEDs and error codes.

  • Inspect wiring for loose connections or burned areas.

  • Replace the board if necessary.

For detailed guides on electrical and safety inspections, consult official Goodman MBVK troubleshooting resources (Goodman Troubleshooting Resources).


Why the Goodman MBVK Makes Troubleshooting Easier

Modern electric furnaces like the Goodman MBVK include several features that make identifying issues like “fan runs but no heat” simpler:

  1. Diagnostic LEDs: Indicate specific faults.

  2. Electronic safety monitoring: Reduces false trips and prevents damage.

  3. Staged heating elements: Gradual energizing of elements reduces overheating risk.

  4. Variable-speed ECM blower: Maintains consistent airflow and pressure, which can prevent false safety trips.

Compared to older systems, MBVK owners benefit from clearer diagnostics and more reliable operation.


Preventing Fan-Without-Heat Problems

Preventive maintenance is the best way to avoid a furnace blower working but no heat scenario:

  • Replace or clean filters regularly (1–3 months).

  • Schedule annual professional furnace inspections.

  • Keep ducts clean and unobstructed.

  • Ensure thermostat is functioning properly.

  • Monitor control board LEDs and address any early warning signs.

By following these steps, homeowners can minimize service interruptions and prolong the lifespan of their Goodman MBVK electric furnace.


When to Call a Professional

While some troubleshooting can be done safely at home, situations requiring professional attention include:

  • Repeated trips of high-limit switches or safety sensors.

  • Burned or melted wiring.

  • Malfunctioning control board or relays.

  • Heating elements that require replacement beyond basic inspection.

Licensed HVAC technicians have the expertise and tools to safely diagnose and repair these issues.


Summary: Fan Runs But No Heat

A furnace fan running but no heat can be caused by several factors: thermostat issues, tripped breakers, faulty heating elements, safety devices, or control board failures. Modern systems like the Goodman MBVK electric furnace make troubleshooting easier with diagnostic features and advanced design.

By understanding the potential causes, following proper troubleshooting steps, and performing regular maintenance, homeowners can ensure their electric furnace delivers reliable, efficient heat when it’s needed most.