If you’ve landed here, chances are you’re staring at a Goodman system that isn’t heating, isn’t behaving, or just did something weird—and now you’re asking the same set of questions I hear every single heating season:
-
goodman furnace reset button
-
how to reset goodman furnace
-
switch goodman furnace reset button
-
where is the reset button on a goodman furnace
-
goodman furnace reset button location
-
goodman furnace reset switch
And if your system is built around a Goodman MBVK electric furnace setup, I’m going to save you some time, some frustration, and possibly a needless service call.
Here’s the straight truth, Jake Lawson style:
There is no single, universal “reset button” on a Goodman MBVK electric furnace.
Not a red button.
Not a magic switch.
Not a hidden lever behind a panel.
But before you feel cheated, let me explain why—because understanding how reset logic works on an electric Goodman system will make you far more effective at troubleshooting than blindly hunting for a button that doesn’t exist.
First things first: what the Goodman MBVK actually is
The Goodman MBVK is an air handler platform, not a traditional gas furnace cabinet. When paired with an electric heat kit, it functions as what homeowners correctly call an electric furnace.
That distinction matters because most “reset button” advice floating around online is written for gas furnaces, which operate very differently.
Gas furnaces:
-
burn fuel
-
use ignition systems
-
rely on flame safety devices
-
often include manual reset limits or rollout switches
Electric furnaces (including MBVK setups):
-
do not burn fuel
-
do not ignite flames
-
do not use pilot lights
-
rely on electrical safeties, not combustion safeties
Goodman’s own product literature makes it clear that the MBVK is designed as a modular air handler with optional electric heat—not a gas-fired unit. You can see how Goodman categorizes and positions the MBVK series directly on their official product page. (Goodman MBVK Series overview)
Once you understand that, the reset-button myth starts to fall apart.
Why people keep searching for a Goodman furnace reset button
When heat stops working, people want a fast, simple fix. A reset button feels reassuring. Push it, problem solved, back to comfort.
So when homeowners search where is the reset button on a goodman furnace or goodman furnace reset button location, what they’re really asking is:
“What do I do to make this thing work again?”
And that’s a fair question.
But electric furnaces don’t fail in a way that’s fixed by pressing a single switch. They fail in layers—power, airflow, controls, and safeties.
The most important thing to understand: reset ≠ reset button
On a Goodman MBVK electric furnace, “resetting” the system usually means interrupting power, allowing safety circuits to reset themselves, and correcting whatever caused the safety to trip in the first place.
There is no labeled goodman furnace reset switch because:
-
most safeties are automatic-reset
-
some are one-time-use
-
others reset only when conditions return to normal
So instead of asking where is the reset button, the better question is:
“What safety or condition caused the system to shut down?”
Let’s break that down.
Common components people mistake for a reset button
1. High-limit switches (not a reset button)
Electric furnaces use high-limit switches to prevent overheating. If airflow is restricted or heat builds too quickly, the limit opens and cuts power to the heating elements.
Most of these limits are:
-
automatic reset
-
temperature-based
-
not manually pressable
When the system cools down, they close again—unless the underlying problem persists.
So if your heat:
-
comes on briefly,
-
shuts off,
-
blower keeps running,
that’s not a reset-button issue. That’s a limit doing its job.
2. Fusible links or thermal cutoffs (definitely not a reset button)
Some electric heat kits include one-time safety devices that permanently open if temperatures exceed safe limits.
Once those trip:
-
there is no reset
-
the part must be replaced
-
the cause must be corrected
Pushing imaginary buttons won’t help.
3. Circuit breakers (this is the closest thing to a “reset”)
If you want something that functions like a reset, breakers are it.
A Goodman MBVK electric furnace often uses:
-
one breaker for the blower/control circuit
-
one or more breakers for electric heat strips
If a breaker trips:
-
the system may run with no heat
-
or not run at all
Turning a breaker fully OFF, then back ON, is the correct reset procedure—not flipping it back and forth blindly.
This is the most common answer to how to reset goodman furnace in electric systems.
The correct way to “reset” a Goodman MBVK electric furnace
Let’s get practical.
If your MBVK-based electric furnace isn’t heating and you’re tempted to search switch goodman furnace reset button, do this instead:
Step 1: Turn the thermostat OFF
Not just down. OFF.
Step 2: Turn OFF power at the breaker(s)
-
Identify all HVAC-related breakers.
-
Turn them fully OFF.
-
Wait 2–5 minutes.
This allows:
-
control boards to power down,
-
safeties to reset (if they’re automatic),
-
relays to fully disengage.
Step 3: Replace the air filter
Do this before restoring power. A dirty filter is the #1 cause of electric furnace limit trips.
Step 4: Restore power
-
Turn breakers back ON.
-
Turn thermostat back to HEAT.
Step 5: Observe behavior
-
Does heat come on and stay on?
-
Does it shut off again?
-
Does the blower run with no heat?
If it shuts down again, stop resetting. Repeated resets without fixing the cause can damage components.
Why Goodman doesn’t include a simple reset button
This part surprises people.
Goodman (and other manufacturers) intentionally avoid giving homeowners a single reset button on electric furnaces because:
-
it encourages repeated resets without diagnosis
-
it can mask airflow or electrical problems
-
it creates unsafe operating conditions
Electric heat elements draw massive current. If something goes wrong, the system is designed to shut down until conditions are safe again—not until someone presses a button and hopes for the best.
Goodman’s installation literature reflects this design philosophy clearly when describing electric heat kit safeties and airflow requirements. (Goodman MBVK installation manual)
The real reasons people think their Goodman furnace needs a reset
Let’s talk patterns I see in the field.
Pattern 1: Heat works, then stops
Usually airflow-related:
-
clogged filter
-
closed registers
-
undersized return
The limit opens, heat stops, blower keeps running.
Pattern 2: Blower runs, no heat at all
Often electrical:
-
tripped heat strip breaker
-
failed sequencer or relay
-
thermostat staging issue
Pattern 3: Heat never comes on
Could be:
-
thermostat wiring issue
-
control board problem
-
no power to heat kit
None of these are solved by pressing a reset button—even if one existed.
Where is the reset button on a Goodman furnace?
Let’s answer that keyword directly:
where is the reset button on a goodman furnace
On a Goodman MBVK electric furnace:
There isn’t one.
There may be:
-
breakers in the panel,
-
automatic reset limits inside the cabinet,
-
one-time safeties in the heat kit,
but there is no homeowner-accessible reset button or switch.
So when people search goodman furnace reset button location, the honest answer is:
It doesn’t exist—because electric furnaces reset through power cycling and safety logic, not manual buttons.
When resetting is a bad idea
This is important.
If your system:
-
keeps tripping breakers,
-
repeatedly loses heat,
-
smells hot or electrical,
-
cycles heat on and off rapidly,
do not keep resetting it.
At that point, the system is telling you something is wrong. Continuing to reset can:
-
damage heating elements,
-
stress wiring,
-
hide a serious airflow issue.
The U.S. Department of Energy emphasizes that electric resistance heating systems rely heavily on proper airflow and electrical integrity for safe operation. (DOE electric heating overview)
The MBVK advantage—when it’s set up correctly
Here’s the good news.
When a Goodman MBVK electric furnace is:
-
properly sized,
-
correctly wired,
-
matched to the right heat kit,
-
set up with correct airflow,
it’s incredibly reliable.
Most “reset button” searches come from:
-
installation issues,
-
maintenance neglect,
-
or misunderstanding how electric heat works.
The equipment itself is rarely the villain.
What to tell someone who says “just hit the reset button”
If a friend, neighbor, or internet commenter tells you to “just hit the reset button” on your Goodman MBVK electric furnace, here’s the translation:
They’re thinking of a gas furnace.
You’re dealing with an electric air handler with resistance heat.
Different animal. Different rules.
The bottom line
Let’s close this out clearly.
-
There is no dedicated goodman furnace reset button on a Goodman MBVK electric furnace.
-
There is no reset switch you flip inside the cabinet.
-
Resetting means power cycling, not pushing a button.
-
If the system keeps shutting down, resetting won’t fix the cause.
If you stop searching for a button that doesn’t exist and start focusing on airflow, power, and controls, you’ll solve the problem faster—and safer.
And once you understand that, you’ll never fall down the “reset button” rabbit hole again.